PubMed Health⌕ Search

PubMed · 3119968

Dose distributions in dynamic stereotactic radiosurgery.

Abstract

A treatment planning technique for calculation of dose distributions in dynamic stereotactic "radiosurgery" with a 10-MV isocentrically mounted linear accelerator is presented. The treatment planning for dynamic radiosurgery is a three-dimensional problem, since during treatment both the gantry and the couch rotate simultaneously, the gantry from 30 degrees to 330 degrees and the couch from 75 degrees to - 75 degrees. The patient surface and anatomical information is obtained from a family of computed tomography or magnetic resonance scans, and a stereotactic frame is used for target localization, treatment setup, and patient immobilization during the treatment. The dose calculational algorithm follows the gantry and couch rotation in an incremental fashion, and relies on measured stationary beam central axis percentage depth doses and dose profiles to calculate the normalized tissue-maximum-ratio distributions over a matrix of points defined on one of three orthogonal planes (transverse, sagittal, or coronal). The dose calculation algorithm is discussed in detail and calculated dose distributions for single plane and dynamic radiosurgery compared with measured data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Pike, E B Podgorsak, T M Peters, C Pla. Dose distributions in dynamic stereotactic radiosurgery.. https://doi.org/10.1118/1.596003

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A penalized likelihood approach to magnetic resonance image reconstruction.

Currently, images acquired via magnetic resonance imaging (MRI) and functional magnetic resonance imaging (fMRI) technology are reconstructed using the discrete inverse Fourier transform. While computationally convenient, this approach is not able to filter out noise. This is a serious limitation because the amount of noise in MRI and fMRI can be substantial. In this paper, we propose an alternative approach to reconstruction, based on penalized likelihood methodology. In particular, we focus on non-linear shrinkage estimators and show that this approach achieves a great reduction in integrated mean squared error (IMSE) of the estimated image with respect to the currently used estimator. This approach is extremely fast and easy to implement computationally. In addition, it can be combined with various alternative approaches to MR image reconstruction and can be easily adapted to other, non-MRI contexts, in which the observed data and the quantities of interest are related via a linear transform.

Brain Diseases↗