PubMed Health⌕ Search

PubMed · 3171257

Total implants for hyperthermia application and thermometry.

Abstract

Tests have been performed in saline phantoms on a 6.78 MHz hyperthermia applicator designed for complete implantation; no conductors would penetrate the skin following the implant procedure. Energy is coupled across the skin from an external to an internal loop antenna: the latter is connected by transmission line to conventional r.f. tissue electrodes which are typically either parallel plates or arrays of cylindrical pins. In phantoms the technique produces deep, localized heating at a selected site without significant hearing at the 'subdermal' receiving antenna near the surface. In addition, the hyperthermia applicator may have potential as an indicator of temperature for the tissue volume at the deep site, since complex impedance at the external antenna is a function of tissue resistivity/temperature at the electrodes. Specifically, temperature at the deep site can be controlled effectively by regulation of the phase angle between voltage and current at the external antenna. A separate passive implantable electromagnetic-reflectance thermometer, energized by external electromagnetic fields, has been designed. This device, also tested in gel and water phantoms, is energized and interrogated by external r.f. fields and tracks a thermocouple to within +/- 0.1 degree C over the range of interest in clinical hyperthermia. The intended application for these devices is repeated, long-term hyperthermic treatment and thermometry of deep-seated malignant tumours following a single invasive procedure.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J D Doss, C W McCabe. Total implants for hyperthermia application and thermometry.. https://doi.org/10.3109/02656738809012401

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development and evaluation of the electromagnetic hypersensitivity questionnaire.

Electromagnetic hypersensitivity (EHS) syndrome is usually defined as a condition where an individual experiences adverse health effects that he or she believes is due to exposure to objects that emit electromagnetic fields. The aim of this study was to develop a questionnaire that would identify the key symptoms associated with EHS and determine how often these symptoms occur in the general population of the United Kingdom. In the pilot study, an EHS questionnaire was developed and tested. In Study 1 the EHS questionnaire was revised and sent to a randomly selected sample of 20,000 people. Principal components analysis of the symptoms resulted in eight subscales: neurovegetative, skin, auditory, headache, cardiorespiratory, cold related, locomotor, and allergy related symptoms. Study 2 established the validity of the questionnaire in that EHS individuals showed a higher severity of symptoms on all subscales compared to the control group. The two key results of this study were the development of a scale that provides an index of the type and intensity of symptoms commonly experienced by people believing themselves to be EHS and a screening tool that researchers can use to pre-select the most sensitive individuals to take part in their research.

Electromagnetic Fields↗

Extremely low frequency weak magnetic fields enhance resistance of NN tobacco plants to tobacco mosaic virus and elicit stress-related biochemical activities.

Increasing evidence has accumulated concerning the biological effects of extremely low frequency magnetic fields (ELF-MFs) in different plant models. In the present study, effects of ELF-MFs in tobacco plants reacting to tobacco mosaic virus (TMV) with a hypersensitive response (HR) were evaluated. Plants were exposed for 8 or 24 h (either before or after TMV inoculation) to a static MF, at either -17 or 13 microT, combined with a 10 Hz sinusoidal MF with different intensities (25.6 or 28.9 microT). The working variables were the area and number of hypersensitive lesions in leaves. Following ELF-MFs exposure, an increased resistance was detected, particularly after an 8-h treatment, as shown by the decrease in lesion area and number. Moreover, two enzyme activities involved in resistance mechanisms were analyzed: ornithine decarboxylase (ODC) and phenylalanine ammonia-lyase (PAL). Uninoculated leaves previously exposed to ELF-MFs in general showed a significant increase relative to controls in ODC and PAL activities, in particular for 13 microT static MF plus 28.9 microT, 10 Hz sinusoidal MF (24 h) treatment. In conclusion, ELF-MFs seem to influence the HR of tobacco to TMV, as shown by the increased resistance and changes in ODC and PAL activities, indicating the reliability of the present plant model in the study of bioelectromagnetic interactions.

Electromagnetic Fields↗