PubMed Health⌕ Search

PubMed · 3176119

Trimethoprim analysis.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I D Watson. 1988. Trimethoprim analysis.. https://pubmed.ncbi.nlm.nih.gov/3176119/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Simultaneous determination of six HIV nucleoside analogue reverse transcriptase inhibitors and nevirapine by liquid chromatography with ultraviolet absorbance detection.

An accurate, sensitive and specific reversed-phase high-performance liquid chromatography assay for the simultaneous quantitative determination of the nucleoside reverse transcriptase inhibitors zalcitabine, lamivudine, didanosine, stavudine, zidovudine, and abacavir with the non-nucleoside reverse transcriptase inhibitor nevirapine in human blood plasma is described. The new Polarity dC C(18) silica column used in this method provides better resolution and peak shape than all other columns tested. Also, four different ultraviolet wavelengths were used for accurate and specific quantitation of the analytes. The method was validated over the range of 10-10000 ng/ml for all analytes except zalcitabine (10-5000 ng/ml). This method is accurate (average accuracies of three different concentrations ranged from 97.2 to 105%), and precise (within- and between-day precision measures ranged from 0.5 to 5.1% and 0.5 to 5.6%, respectively), and is currently being used for determination of plasma drug concentrations in our laboratory.

Chromatography, High Pressure Liquid↗

Pharmaceutical profiling method for lipophilicity and integrity using liquid chromatography-mass spectrometry.

A method is described for the simultaneous profiling of sample lipophilicity, integrity, and purity. The method is rapid and is applicable to high throughput profiling of pharmaceutical properties in drug discovery. A short Polaris C(18) column is used with a rapid, wide-polarity mobile phase gradient, UV detection, and MS analysis. The lipophilicity of each component is estimated from a calibration curve using six drug or organic compounds and plotting their respective measured retention time versus LogD(7.4) (literature). The correlation of LogD(7.4) (literature) to LogD(7.4) (HPLC) for 60 structurally diverse drugs has a correlation coefficient r(2) of 0.89. The method is applicable to compounds with MW>200 and retention time>1.5 min for rapid, initial pharmaceutical profiling in drug discovery.

Chromatography, High Pressure Liquid↗

A mass spectrometric validated high-performance liquid chromatography procedure for the determination of folates in foods.

A series of five food reference materials (RM) that had certified values of folate concentrations and five frozen food samples were analyzed for 5-methyltetrahydrofolic acid (5-MTHFA) and folic acid (FA) using a high-performance liquid chromatography (HPLC) method with fluorescence detection that was validated using an HPLC mass spectrometry (MS) method with electrospray ionization. Identical sample specimens were extracted and analyzed in triplicate using both instrumental methods, and a comparison was made of the mean values of 5-MTHFA and FA resulting from these determinations. The analytes were isolated on either a high capacity strong anion exchange solid phase extraction column (HPLC method) or a phenyl Bond Elut column (MS method) prior to analyses. For quantification of the analytes by MS, (13)C-labeled 5-MTHFA and FA were added to samples as internal standards prior to enzymatic digestion and conversion of the polyglutamate forms of 5-MTHFA to the monoglutamic acid. Quantification of FA and 5-MTHFA using the HPLC analysis was carried out using external standards. With the exception of one RM (pig liver), the values established for 5-MTHFA using these methods were highly comparable. In determining the variance associated with these two procedures, it was observed that the mean relative standard error for 5-MTHFA was 12 (range, 2-27%) and 11% (range, 5-25%) for the HPLC and MS methods, respectively. FA was detected in only three of the samples, and the values obtained for it by either method were similar. This is the first paper that describes a mass spectrometric method used in the validation of an HPLC determination of food folates across a wide range of sample matrixes. The comparable values for 5-MTHFA and FA suggest that HPLC analysis with fluorescent detection may be used to accurately quantify folates present in a variety of food matrixes.

Chromatography, High Pressure Liquid↗