An EPROM-based programmable contour generator for use in flow cytometry.

Abstract

An erasable programmable read-only memory (EPROM) contour generator has been fabricated to produce contours for use in flow cytometry. Contours are analog waveforms representing the fluorescence or light-scatter intensity distribution along a cell or object. The generator has particular utility in the development and testing of slit-scan instrumentation and analysis algorithms. Contours are generated without the requirement of specimens or full operation of the flow instrumentation. The generator provides control of contour height, width, offset, and rate. The EPROM may be custom programmed to produce contours for specific test applications or for reproducing "real" contour events. The generator is useful in situations where constant repetitive contours of predetermined characteristics are required.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D M Wheeless, J L Cambier, L L Wheeless. 1988. An EPROM-based programmable contour generator for use in flow cytometry.. https://doi.org/10.1002/cyto.990090514

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dosimetric pre-treatment verification of IMRT using an EPID; clinical experience.

BACKGROUND AND PURPOSE: In our clinic a QA program for IMRT verification, fully based on dosimetric measurements with electronic portal imaging devices (EPID), has been running for over 3 years. The program includes a pre-treatment dosimetric check of all IMRT fields. During a complete treatment simulation at the linac, a portal dose image (PDI) is acquired with the EPID for each patient field and compared with a predicted PDI. In this paper, the results of this pre-treatment procedure are analysed, and intercepted errors are reported. An automated image analysis procedure is proposed to limit the number of fields that need human intervention in PDI comparison. MATERIALS AND METHODS: Most of our analyses are performed using the gamma index with 3% local dose difference and 3mm distance to agreement as reference values. Scalar parameters are derived from the gamma values to summarize the agreement between measured and predicted 2D PDIs. Areas with all pixels having gamma values larger than one are evaluated, making decisions based on clinically relevant criteria more straightforward. RESULTS: In 270 patients, the pre-treatment checks revealed four clinically relevant errors. Calculation of statistics for a group of 75 patients showed that the patient-averaged mean gamma value inside the field was 0.43 +/- 0.13 (1SD) and only 6.1 +/- 6.8% of pixels had a gamma value larger than one. With the proposed automated image analysis scheme, visual inspection of images can be avoided in 2/3 of the cases. CONCLUSION: EPIDs may be used for high accuracy and high resolution routine verification of IMRT fields to intercept clinically relevant dosimetric errors prior to the start of treatment. For the majority of fields, PDI comparison can fully rely on an automated procedure, avoiding excessive workload.

Electronic Data Processing↗

The emergence of radiofrequency identification tags: applications in surgery.

Radiofrequency identification (RFID) is a wireless method of automatic identification. Currently, RFID tags are emerging into our environment in many aspects of our lives. Applications are being developed in a variety of fields, including health care. Aspects of surgical care will lend themselves to this approach. This technology could provide large amounts of data that not only carry the promise of improving health care, but also may have an impact on personal aspects of our daily lives. Each of us must become familiar with the risks and benefits of RFID use.

Electronic Data Processing↗