PubMed HealthSearch

PubMed · 3190332

Pericardial substitutes: a survey.

Abstract

Many thoracic surgeons have used pericardial substitutes to reduce the risk of reoperation, but there have been few reports of these procedures. Therefore, we used a questionnaire to gather information on experience with use of pericardial substitutes and to document the findings at reoperation. A six-question survey was sent to 2,344 members of The Society of Thoracic Surgeons, requesting surgeons to list their experience with pericardial substitutes and at reoperation in patients with these substitutes in place. Of the 634 surgeons who responded to the survey, 120 reported the insertion of 3,828 pericardial substitutes. Two hundred thirty-six reoperations were reported by 89 surgeons. None of the pericardial substitutes was reported to be completely successful in facilitating reoperation. The experience with polytetrafluoroethylene (PTFE) pericardial substitutes was reported to be significantly more satisfactory than that with all other substitutes (p = 0.0004 by chi-square analysis), but 14% of surgeons who used PTFE said they were dissatisfied at reoperation. Based on the results of this survey, we suggest caution, careful documentation, and long-term follow-up studies before widespread use of pericardial substitutes can be recommended.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W H Heydorn, V A Ferraris, W R Berry. 1988. Pericardial substitutes: a survey.. https://doi.org/10.1016/s0003-4975(10)64699-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Value of routine follow-up after infrainguinal arterial reconstruction].

Longterm patency of infrainguinal bypass procedures may be established on the basis of clinical evaluation and ankle pressure measurements. With the aim of assessing whether these parameters could predict grafts at risk for occlusion, we identified 24 patients in whom the bypass had occluded between 3 and 12 months postoperatively, but following at least one follow-up. These patients were compared with a control group consisting of further 24 patients operated on during the same period, but in whom the bypass was patent. Prior to graft occlusion only nine (39%) patients had complained of claudication, and a significant drop in ankle pressure was demonstrated in seven (29%) patients. These figures were significantly higher than the one (4%) patient in the control group who complained of claudication and the other (4%) patient who developed a drop in ankle pressure (p < 0.02 and 0.05, respectively). Graft surveillance based on patients' history and ankle pressure measurements are insufficient parameters for identification of grafts at risk for occlusion. However, the occurrence of claudication and/or a significant drop in ankle pressures are associated with a high incidence of graft thrombosis.

Biocompatible Materials

[Implantation of a Stecker metal prosthesis in malignant stenosis of the gastric stump].

A 55 year old patient 3 years after gastric resection (Billroth II) has got gastric outlet stenosis. Half year ago was established a tumour recidive, that the time of reoperation was inoperable. Under endoscopic and radiological control we have introduced and placed a 19 mm diameter, 4 cm long balloon expandable tantalum stent (Strecker stent). The gastric passage has normalised and after 6 month the patient is symptom free.

Biocompatible Materials