PubMed · 3201199
A new method for finishing minicavities.
Abstract
Minicavities were prepared in 26 caries-free teeth. Cavity preparation and the finishing of the occlusal area and the gingival floor was done with diamond burs (diameter 1 mm, grain sizes 90 micron and 15 micron, respectively). For the finishing of the axial box margin and the proximo-cervical curved border, a new set was developed: It is composed of an EVA-system with the total amplitude reduced to 0.34 mm, and a highly flexible file (Cavishape, grain 15 micron). The shape of this file had to be modified in order to follow the proximo-cervical curvature. The efficiency of the new device was compared with the axial margin trimmer by means of scanning electron microscopy and a score system. The new device allowed a significantly better finishing of the proximo-cervical curvature and of the axial box margin.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
A Lussi, M Gygax, P Hotz, D Lüthi. 1988. A new method for finishing minicavities.. https://pubmed.ncbi.nlm.nih.gov/3201199/