PubMed Health⌕ Search

PubMed · 320607

Interaction between thiamine hydrochloride and lipoic acid.

Abstract

An interaction between thiamine hydrochloride and DL-alpha-lipoic acid in aqueous solution was depicted. Evidence is presented through spectrophotometric as well as vapour pressure measurements to show that thiamine hydrochloride and DL-alpha-lipoic acid form a single 1:1 complex. The stability constant and the molar extinction coefficient of the complex (at 244 nm) were determined at 25 degrees C and found to be 3.1-10(4) and 970, respectively. Vapour pressure measurements at 60 degrees C reveal that more or less complete dissociation of the complete takes place at this temperature.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H O Ammar, H A Salama. 1977. Interaction between thiamine hydrochloride and lipoic acid.. https://pubmed.ncbi.nlm.nih.gov/320607/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Direct on-line method to monitor the dynamic structure of noncovalent titanium complexes in solution by using cold-spray ionization time-of-flight mass spectrometry.

In this paper, we report the feasibility of using the on-line cold-spray ionization time-of-flight mass spectrometry (CSI-TOFMS) method to monitor directly the labile noncovalent organometallic complexes formed in the substitution reaction between a chiral titanium asymmetric catalyst and organic acid in the toluene solvent. The comparison between the conventional ESI and CSI-TOFMS spectra of [(S)1]2Ti2[(S)2]2 in THF indicated that the CSI-TOFMS is an effective method to characterize the structures of labile organometallic complexes in solution. A new strategy was designed so that [(S)1]2Ti2[(S)2]2 and organic acid solution were delivered independently to the CSI ion source by two infusion syringe pumps, and they mixed at a triple valve, and then the substitution reaction occurred in the sprayer. The mix and reaction time was approximately 5 s and can be adjusted by the length of the PEEK tube and the flow rate. The reaction products were ionized and detected directly by the CSI-TOFMS. Organic acids, such as formic, acetic, phenylpropionic, anisic, and para-methoxylphenylactic acids, were investigated. From the on line CSI-TOFMS spectra, it is observed clearly that one or two (S)2 group(s) can be substituted by the added acid to form new species. The results obtained here demonstrated that the designed strategy with on line CSI-TOFMS is effective and reliable to elucidate the dynamic structure of noncovalent titanium complexes in reaction solution.

Solutions↗

Sensitometric comparisons of Insight and Ektaspeed Plus films: effects of chemical developer depletion.

The aim of this study was to compare the sensitometric properties of Insight and Ektaspeed Plus radiographic films manually and automatically processed using fresh and depleted chemical solutions. Ten sets of each type of film were obtained (1 set = 5 films), 5 sets being manually processed and 5 sets being automatically processed. A total of 100 films (50 Ektaspeed Plus and 50 Insight film) were exposed and developed. The first two sets of each film type were developed in fresh chemicals (one set per each type of processing), on the first day of the experiment. The other sets were processed in the same progressively depleted solutions once a week until the end of experiment, which was completed within 4 weeks. Characteristic curves were constructed to compare the sensitometric properties of the films: contrast, latitude and speed. Processing solution depletion had different effects on manually and automatically developed films, which was confirmed by the changes in the form of the characteristic curves in the third week of the automatic processing and fourth week of the manual processing. Ektaspeed Plus showed 11% reduction in contrast values for manual processing and 53% for automatic processing, while Insight contrast values showed a reduction of 25% and 59%, respectively. Insight film, however, showed lesser loss of speed and lesser increase of latitude than Ektaspeed Plus. In conclusion, chemical depletion in automatic film processing was faster than in manual developing. In depleted chemicals, both types of films had an increase in latitude values and a decrease in speed and contrast. Insight was more resistant than Ektaspeed Plus to decrease in speed and latitude when processed using older chemicals, whereas contrast in Ektaspeed Plus was comparatively more stable.

Solutions↗