A new analytical methodology for the determination of fully methoxylated flavones (FMFs) in citrus juices is described. Isolation of the FMFs is carried out by percolation of 30 mL of clarified citrus juice (to which tetramethyl-o-kaempferol is previously added as internal standard) through a C18 Sep-Pak cartridge, washing with 3 mL of water followed by 5 mL of water/acetonitrile (3:1), and selective elution of the retained FMFs with 5 mL of water/acetonitrile (9:11). Determination of the isolated FMFs is carried out by reversed-phase high-performance liquid chromatography (HPLC) and UV diode array detection (DAD). Signals at wavelengths 320, 335, and 345 nm (bandwidth 4 nm) are simultaneously acquired, stored, plotted, and integrated. The column used is a microbore (200 x 2.1-mm) Hypersil ODS 5 microns. Elution is in gradient mode, using a ternary mobile phase (water/acetonitrile/tetrahydrofuran). Column temperature is 40 degrees C. Recovery yields are nearly 100% for all the FMFs detected and identified: isosinensetin, hexamethyl-o-gossypetin, sinensetin, tetramethyl-o-isoscutellarein, hexamethyl-o-quercetagetin, nobiletin, tetramethyl-o-scutellarein, heptamethoxyflavone, and tangeretin. Chromatographic separation of the FMFs is extremely dependent upon the minor changes of the mobile phase composition and percentages, gradient rate, and temperature. The UV spectra (230 to 400 nm) of the FMFs obtained under chromatographic conditions are given. The FMFs relative response factors at 320, 335, and 345 nm and their concentrations in hand-squeezed and commercial concentrated orange and mandarin juices are tabulated. The FMF concentration differences found among samples are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J M Sendra, J L Navarro, L Izquierdo. 1988. C18 solid-phase isolation and high-performance liquid chromatography/ultraviolet diode array determination of fully methoxylated flavones in citrus juices.. https://doi.org/10.1093/chromsci%2F26.9.443

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quantitative determination of glucose in blood plasma and in fruit juices by combined WATR-CPMG 1H NMR spectroscopy.

The quantitative analysis of pure glucose solution < or = 225 mM (< or = 40.8 mg/mL) in 90/10 H2O/D2O was successfully completed in dilute aqueous solution by the WATR-CPMG method whereby the T2 of the water resonance is manipulated by the WATR method followed by elimination of the water peak by the CPMG pulse sequence. The method was applied to the quantitative analysis of total glucose in blood plasma from human subjects undergoing the oral glucose tolerance test in the teaching hospital, and the results were compared to those obtained using a standard glucose oxidase method in a hospital chemical pathology laboratory. The accuracy of the results obtained using the WATR-CPMG method were generally within 5% of the glucose oxidase method. The coefficient of variation was determined to be better than 4% using plasma samples of diabetic subjects. Application to the quantitative analysis of orange and guava juice was also successfully demonstrated.

Beverages

Solventless determination of caffeine in beverages using solid-phase microextraction with fused-silica fibers.

Caffeine concentrations in beverages were determined using a simple and rapid method based on microextraction of caffeine onto the surface of a fused-silica fiber. The uncoated fiber was dipped into the beverage sample for 5 min after the addition of isotopically labeled (trimethyl 13C)caffeine. The adsorbed caffeine was then thermally desorbed in a conventional split/splitless injection port, and the concentration of caffeine was determined using gas chromatography with mass spectrometric detection. Quantitative reproducibilities were ca. 5% (relative standard deviation) and the entire scheme including sample preparation and gas chromatographic analysis was completed in ca. 15 min per sample. The potential of the microextraction technique for the analysis of flavor and fragrance compounds in non-caffeinated beverages is also demonstrated. Since no solvents or class-fractionation steps are required, the method has good potential for automation.

Beverages