PubMed HealthSearch

PubMed · 3244973

Developments in processing image sequences for elemental mapping.

Abstract

Elemental mapping consists in searching the distribution of a given chemical species over an extended specimen area, with relation to topographical or structural features. It can be done with EELS core signals from a combination of several energy filtered images. One major problem encountered in the processing of such sequences of images lies in the extrapolation errors due to a difficult estimate of the background below the characteristic signal. The chosen method must be sufficiently reliable to avoid the risk of both "false positive" and "false negative" values: the first category may stem from spurious signals or from a non-satisfactory fit of the background. The second category is mainly due to a limited sensitivity. The EELS signal is often much weaker than the background intensity; an extrapolation error can therefore transform a negative value into a positive one, or vice versa. The purpose of the present contribution is to check the validity of the processing at different levels: i) different mathematical models of background; ii) different types of fitting procedures (one-parameter and two-parameters fits); iii) different fitting methods and several associated manipulations, such as a quasi local estimation of the involved fitting parameters. The statistical validity of those techniques is discussed through several tests on real images obtained from different specimens (Co/CeO2 catalysts, ferritin molecules, U and Tb staining clusters). Progress is made on the way of quantitative elemental mapping at a given confidence level, and towards the identification of single atoms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Bonnet, C Colliex, C Mory, M Tence. 1988. Developments in processing image sequences for elemental mapping.. https://pubmed.ncbi.nlm.nih.gov/3244973/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Characterisation of the ultrastructure of glass-ionomer (poly-alkenoate) cement.

Set glass-ionomer cements were sectioned with a diamond knife and examined in the transmission electron microscope. Their appearance was in accordance with the theoretical structure of these materials, close examination revealing glass particles surrounded by a siliceous layer set in a hydrogel matrix. The elemental composition of each region was determined by X-ray microanalysis (energy dispersive). The results of microanalysis supported the ultrastructural observations, with ions that originated from the glass particles being detected throughout the matrix of the set cement. It was suggested that the mobility of these ions in the matrix phase was important in determining the biocompatibility and adhesive properties of glass-ionomer cements.

Electron Probe Microanalysis

Resonance-enhanced x-rays in thin films: a structure probe for membranes and surface layers.

An x-ray resonance effect in an organic thin film on an x-ray reflecting mirror is reported. The resonance effect is the result of interference between reflected and refracted x-rays at the air-organic thin film interface and occurs at incident angles slightly above the critical angle of the film. In excellent agreement with theory, the primary resonant x-ray electric field that is confined in the organic thin film is approximately 20 times as intense as the electric field of the incident beam when measured at a position close to the center of the film. Resonance-enhanced x-rays can be used to characterize the internal structure of Langmuir-Blodgett thin film membranes. This effect may also find use in x-ray-based thin film devices and in the structural analysis of adlayers and surfaces that have thus far proved difficult, if not impossible, to study because of sensitivity limitations.

Electron Probe Microanalysis

Assessment of trace element compatibility in total parenteral nutrition infusions.

The application of X-ray energy dispersive spectroscopy to detect elements collected from TPN mixtures on membrane filters has been investigated. Many simple total parenteral nutrition mixtures prepared aseptically in large bags can be stored for extended periods. Trace elements are normally excluded from such bags, because not enough is known about their long-term stability and compatibility in total parenteral nutrition mixtures. Assessing the compatibility of many trace elements by conventional methods that rely on detecting concentration changes is extremely difficult. Analysis of precipitates from total parenteral nutrition mixtures confirmed that the proposed method was capable of identifying a number of elements from the mixture in complex precipitates, including calcium, phosphorus, iron, copper and selenium.

Electron Probe Microanalysis