PubMed · 3273930

Portable volume ventilators.

Abstract

We evaluated five portable volume ventilators from four manufacturers. Ventilation requirements in general patient care areas in the hospital differ from those for home care; therefore, we considered use of the units for these applications separately. None of the units was ideal for either application because of the limitations and risks of each ventilator. All units were rated Conditionally Acceptable, but were ranked for hospital use only. The primary conditions for acceptable hospital use were that exhaled-volume monitoring be performed for all patients and that O2 monitoring be performed both when setting FIO2 and continuously when FIO2 levels are critical. For home care, users should carefully weigh the advantages and disadvantages of each unit and base their choice of a unit primarily on individual patient needs, ease of use, and safety factors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

1988. Portable volume ventilators.. https://pubmed.ncbi.nlm.nih.gov/3273930/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Transjugular intrahepatic portosystemic stent shunt (TIPSS) with use of Rösch-Uchida transjugular liver access set--evaluation by CT and its clinical application].

Appropriateness of the Rösch-Uchida transjugular liver access set designed for TIPSS procedure was confirmed, especially about the catheter angle and effective length of the 20 G puncture needle, by CT analysis on three dimensional vascular anatomy of the liver. Clinically, TIPSS using the set was successfully made for two patients, connecting superior right hepatic vein with right portal vein in one patient and middle hepatic vein with left portal vein in another patient with hypoplastic right portal vein. Prior to TIPSS procedure, verification of vascular anatomy on CT images is the key to success of TIPSS in safe.

Evaluation Studies as Topic

[Testing an ultrasonic scanner for determination of urinary bladder volume].

Bladderscan BVI 2000 is a portable ultrasound scanner, specially constructed for determination of bladder volume. We have tested this scanner for accuracy, systematic errors and the training required to use it. The bladder volumes measured by ultrasound scanning were compared with the true volumes. Fifty-six measurements were made. We found the accuracy of BVI 2000 sufficient to determine bladder volumes as either small or large. We found no systematic errors. No special training is required to use the scanner. The device is thus useful in most clinical situations when greater accuracy than indicated here is not necessary.

Evaluation Studies as Topic