Two radiosurgical procedures using a stereotactic frame and a linear accelerator X ray beam with a circular field diameter between 0.5 and 3 cm are presented. One technique is based on a single plane rotation (single plane radiosurgery) whereas the other uses simultaneous and continuous motions of both the gantry (approximately 360 degrees) and couch (approximately 180 degrees) during the radiosurgical procedure (dynamic radiosurgery). The dose, typically a few thousand cGy, is prescribed to the 90% isodose line which just covers the target volume. The dose fall-off outside the spherical target volume is considerably sharper for the dynamic rotation than for the single plane rotation, and is comparable to the dose fall-off obtained with the two presently known dedicated radiosurgical techniques: one based on focused cobalt beams and the other on proton beams. The dose fall-off in the dynamic radiosurgery discussed here is also comparable to that of previously described linear accelerator based multiple converging are techniques, making the dynamic radiosurgery an attractive alternative to presently known radiosurgical procedures. The radiation beam parameters are discussed and the stereotactic frame described. The dose distributions for both radiosurgical techniques are calculated in a single plane and then corrected for the attenuation effects in the stereotactic frame (approximately 2%) and for the effects of the dynamic rotation (approximately 2%). The skin doses are 0.7% and 2%, and the lens doses, if the beam passes through the eyes, are 2.5% and 3.5% for the dynamic rotation and single plane rotation, respectively. The scatter and leakage dose for the radiosurgical procedures is typically 0.2% to the patient's thyroid, 0.06% to the breast, and 0.02% to the gonads.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E B Podgorsak, A Olivier, M Pla, P Y Lefebvre, J Hazel. 1988. Dynamic stereotactic radiosurgery.. https://doi.org/10.1016/0360-3016(88)90059-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Clinical approach to genetic cardiomyopathy in children.

BACKGROUND: Cardiomyopathy (CM) remains one of the leading cardiac causes of death in children, although in the majority of cases, the cause is unknown. To have an impact on morbidity and mortality, attention must shift to etiology-specific treatments. The diagnostic evaluation of children with CM of genetic origin is complicated by the large number of rare genetic causes, the broad range of clinical presentations, and the array of specialized diagnostic tests and biochemical assays. METHODS AND RESULTS: We present a multidisciplinary diagnostic approach to pediatric CM of genetic etiology. We specify criteria for abnormal left ventricular systolic performance and structure that suggest CM based on established normal echocardiographic measurements and list other indications to consider an evaluation for CM. We provide a differential diagnosis of genetic conditions associated with CM, classified as inborn errors of metabolism, malformation syndromes, neuromuscular diseases, and familial isolated CM disorders. A diagnostic strategy is offered that is based on the clinical presentation: biochemical abnormalities, encephalopathy, dysmorphic features or multiple malformations, neuromuscular disease, apparently isolated CM, and pathological specimen findings. Adjunctive treatment measures are recommended for severely ill patients in whom a metabolic cause of CM is suspected. A protocol is provided for the evaluation of moribund patients. CONCLUSIONS: In summary, we hope to assist pediatric cardiologists and other subspecialists in the evaluation of children with CM for a possible genetic cause using a presentation-based approach. This should increase the percentage of children with CM for whom a diagnosis can be established, with important implications for treatment, prognosis, and genetic counseling.

Brain Diseases

No blindsight following hemidecortication in human subjects?

Using a guessing paradigm we measured visual sensitivity in the blind and normal half-fields of four cerebrally hemidecorticated patients. In the blind field, sensitivity was reduced by approximately 3 long units. Stimuli which produced significant detection also evoked conscious sensations of light and colour. Control experiments showed that although sensitivity in the blind field depended in a normal fashion on background luminance it was independent of the luminance of a local platform, and showed no spatial summation. This residual vision can be explained by intraocular light diffusion and reflection.

Brain Diseases