Scuba diving injuries.

Abstract

Scuba diving has become increasingly popular, and family physicians may encounter patients who have been injured in a dive. Manifestations of diving injuries may not occur until 12 hours or more after a dive. Initial treatment, based on knowledge of the pathophysiology of decompression sickness, lung expansion injuries and ear barotrauma, may prevent severe and permanent sequelae. Decompression sickness and air embolism are medical emergencies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W H Replogle, S D Sanders, J E Keeton, D M Phillips. 1988. Scuba diving injuries.. https://pubmed.ncbi.nlm.nih.gov/3289337/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Analysis of evoked and spontaneous quantal release at high pressure in crustacean excitatory synapses.

The cellular mechanisms underlying the effect of high pressure on synaptic transmission were studied in the opener muscle of the lobster walking leg. Excitatory postsynaptic currents (EPSCs) were recorded using a loose macropatch-clamp technique at normal pressure and 3.5, 6.9 MPa helium pressure. Responses of the single excitatory axon could be grouped into two types: low-yield (L) synapses exhibiting small EPSCs with a considerable number of failures, and high-yield (H) synapses having larger EPSCs with very few failures. High pressure reduced the average EPSC amplitude in all synapses and shifted their amplitude histograms to the left by decreasing the quantal content (m) without changing their quantum current (q). A binomial distribution fit of EPSC amplitudes revealed that high pressure greatly decreased n, the number of available active zones, but the effect on p, the probability of release for each zone, was not consistent. Many of the spontaneous miniature EPSCs (mEPSCs), observed only in L-type synapses, were "giant" (size = 2-5 q). High pressure increased the frequency of the giant mEPSCs but had little effect on their amplitude histogram. High pressure depressed evoked synaptic transmission by modulating the presynaptic quantal release parameters, but concomitantly enhanced spontaneous quantal release by an unknown mechanism.

Air Pressure

[Flow pattern of respiratory gases in superimposed high-frequency jet ventilation (SHFJV) with the jet laryngoscope].

High-frequency ventilation techniques have been applied for a number of years for laryngeal surgery in order to ventilate patients without endotracheal tubes or catheters. A further development of high-frequency jet ventilation (HFJV) is the technique of superimposed HFJV (SHFJV), which was achieved by combining low- and high-frequency jet streams. Although good clinical results were observed, which have been published in the past, the clinical details of development of SHFJV have not been previously published. METHODS. In order to understand and study the mechanism of superimposition of a high-frequency jet stream, extensive experiments on a lung simulator at defined measuring points, which represented the operating field in microlaryngeal surgery and the trachea, were conducted prior to the clinical application of SHFJV. RESULTS. The measurements demonstrated that superposition of the two jet streams led to greater velocity during inspiration, and therefore produced an increase in tidal volume and entrainment of inspiratory gas. This demonstrates that it is possible to apply a HFJV technique in patients even with an open system. During expiration, the velocity of the low-frequency gas stream is decreased by the opposing flow of the high-frequency jet stream, leading to the buildup of positive end-expiratory pressure. The pulsations of the high-frequency jet stream induce continuous alveolar ventilation. The positioning of the jet nozzles in the jet laryngoscopy has the result that the velocities are already decreased at the tip of the laryngoscope and decrease further with distance from the nozzles. This prevents possible damage to the laryngeal mucosa.

Air Pressure

Silane to enhance the bond between polymethyl methacrylate and titanium.

The machined surface of wrought titanium frameworks used in implant-supported, fixed prostheses does not bond well with acrylic resin. Surface pretreatment has been suggested to enhance the retention of polymethyl methacrylate to machined titanium surfaces. This study evaluated a new bonding material (Rocatec) to determine its effect on the bond strength between titanium and polymethyl methacrylate. Twenty rod-shaped specimens of grade 2 titanium (7.6 x 0.3 cm in diameter) were divided into two groups of 10 samples. Group A received no pretreatment and group B was pretreated with 110 microns alumina air abrasive and the Rocatec material. Heat-cured denture base resin was processed around each titanium sample in a cylindrical shape approximately 0.9 x 1.5 cm. A Shell-Nielsen shear test was performed with a universal testing machine at a crosshead speed of 0.5 mm/minute to determine the bond strength in megapascals (MPa). Group B specimens (23.8 +/- 1.78 MPa) had a shear strength 68% greater than group A (16.1 +/- 1.61 MPa) (p 0.0001). The results of this study indicated that surface pretreatment of grade 2 titanium with 110 microns alumina air abrasive plus Rocatec bonding material significantly enhances the shear bond strength to PMMA.

Air Pressure