Relationship between ozone exposure and pulmonary function changes.

Abstract

A detailed comparison of literature-reported averaged decrements in pulmonary function of normal subjects exposed to O3 has been undertaken. The data base was formed by including data published during the past 20 yr from studies that reported at least one of the pulmonary function variables (forced vital capacity, forced expiratory volume at 1 s, mean forced expiratory flow between 25 and 75% of forced vital capacity, and airway resistance) acquired at 2 h of exposures utilizing either original or modified Bates-Hazucha (intermittent exercise) protocol and that satisfied selection criteria. The final set of data (24 studies involving 299 subjects) was divided by ventilation rate (exercise loads) into four categories: light, moderate, high, and very high ventilation level. For each pulmonary function variable and ventilation level a quadratic function has been fitted to the data using regression procedures. The curve parameter estimates have been computed, tabulated, and statistically evaluated. The slope (quadratic coefficient) for each variable within a group and almost all variables between groups were significantly different from zero and from each other at P less than or equal to 0.0001.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Hazucha. 1987. Relationship between ozone exposure and pulmonary function changes.. https://doi.org/10.1152/jappl.1987.62.4.1671

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Evaluation of ventilatory function of the small airways].

The results of functional tests and the values of flow-volume and spirometric parameters were reevaluated in 1174 randomly selected patients with no evidence of heart disease. There were 533 patients with normal ventilation and 327 patients with no restrictive disorders. In the latter group 11% of the patients had normal FEV1 and lowered FEF50 and FEF75 values. In those patients obstructive changes would not have been found if expiratory flow rates had not been taken into account as one of the criteria for evaluating airway obstruction. In further 13% of the patients a mild airway obstruction would have been found had only FEV1 been evaluated without taking account of expiratory flow rates. It is concluded that expiratory flow rates along with anamnestic data and clinical status are important indicators of obstructive changes of ventilation, especially as they serve to identify functional disorders while these are still reversible and therapy can be useful.

Forced Expiratory Flow Rates

Pulmonary function in newborns after repair of congenital diaphragmatic hernia.

Congenital diaphragmatic hernia (CDH) is associated with pulmonary hypoplasia that limits survival, but the nature and extent of pulmonary dysfunction in neonates with CDH have not been studied. We performed pulmonary function tests (PFTs) in eight intubated infants who survived neonatal repair of CDH (wt, 3.33 +/- 0.15 kg; age, 20.1 +/- 2.7 d; mean +/- S.E.M.). PFTs obtained from six full-term infants (wt, 3.56 +/- 0.15 kg; age, 25.0 +/- 3.3 d) with no respiratory illness served as controls. The deflation flow-volume curve technique produced maximum expiratory flow-volume (MEFV) curves, giving reproducible measurements of forced vital capacity (FVC) and maximal expiratory flow at 25% of FVC (MEF25). Respiratory system compliance (Crs) and resistance (Rrs) were obtained with a modified passive mechanics technique. In seven of eight infants PFTs were repeated after nebulized bronchodilator (0.1% isoetharine). In neonates surviving CDH repair, as compared to those with normal lung function, FVC was significantly reduced (20.78 +/- 3.32 vs. 39.83 +/- 3.30 mL.kg-1, P less than 0.05). MEF25 was also markedly reduced (20.78 +/- 3.32 vs. 39.83 +/- 3.30 mL.kg-1.s-1, P less than 0.05), indicating lower airway obstruction. After administration of nebulized bronchodilator, PFTs showed significant increases from control values in both FVC (15.9%) and MEF25 (200%) without changes in Crs and Rrs. These findings indicate that neonates with CDH have restrictive lung defects, reflecting hypoplasia. After surgical repair and mechanical ventilation airway reactivity develops, primarily in smaller airways, and this may complicate the postoperative course.

Forced Expiratory Flow Rates