Modern acrylics for post-embedding immunostaining techniques.

Abstract

We describe two methods for rapid processing of biological tissues into LR White acrylic plastic. Both methods make use of LR White's compatibility with small amounts of water, enabling non-osmicated tissue to be only partially dehydrated before infiltration with the plastic, a procedure that improves the sensitivity of post-embedding immunocytochemistry. In addition, both methods are designed to reduce the time for which tissue is exposed to the damaging influence of the plastic monomer, which can cause extraction and sudden shrinkage. The tissue example used in the first method is immersion-fixed, surgically removed human pituitary which, by virtue of its thorough fixation, can be processed quickly at 50 degrees C using catalytic polymerization at room temperature. The concentration of the catalyst is critically set to prevent the temperature rising above 60 degrees C in the tissue blocks. Penetration of immunoperoxidase reagents into 330-nm LR White sections is demonstrated and possible modes of action are discussed. When "lightly" fixed tissue is processed as above, serious polymerization artifacts can result from autocatalysis. A second method, based on the first but employing slower polymerization at 0 degrees C, has therefore been developed. The high level of fine structure that can be retained using this method is illustrated by the demonstration of the trans-tubular Golgi in perfusion-fixed kidney of rat. Biotinylated lectin is localized to cells of the kidney proximal tubule with streptavidin-colloidal gold, to illustrate tissue reactivity. In a second example, the structure of the bacterial cell envelope is shown to be similar in appearance after partial dehydration and LR White embedding to that seen after progressive lowering of temperature, dehydration, and Lowicryl embedding.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G R Newman, J A Hobot. 1987. Modern acrylics for post-embedding immunostaining techniques.. https://doi.org/10.1177/35.9.3302021

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Different antigenic nature in apparently healthy women with high serum CA 125 levels compared with typical patients with ovarian cancer.

BACKGROUND: CA 125 is a representative ovarian cancer-associated antigen defined by monoclonal antibody OC125. Recently, monoclonal antibodies were produced (designated 130-22 and 145-9) that were reactive with CA 125 but bound to a separate epitope named CA 130. There was a close correlation between serum CA 125 and CA 130 values in most instances. However, among more than 8000 serum samples, 5 apparently normal women had high serum CA 125 values, despite having normal CA 130 values. In this study, the antigenic nature of these five women was investigated. METHODS: Using gel chromatography, the molecular masses of CA 125 and CA 130 were estimated that were found in the five women with false-positive CA 125 values. The sera were examined using double-determinant assays combining iodine-125-labeled OC125 or iodine-125-labeled 130-22 with OCI25-coated or 145-9-coated beads. RESULTS: The molecular masses of both CA 125 and CA 130 were estimated as greater than 1000 kilodaltons (KD); the CA 130 mass from one of the five women with an abnormal CA 125 level was approximately 200 KD using gel chromatography. Using the double-determinant assays that combined iodine-125-labeled OC125 or iodine-125-labeled 130-22 with OC125-coated or 145-9-coated beads, high radioactivity was found only in the homologous assay using iodine-125-labeled OC125 with OC125-coated beads. These results suggest that the antigenic nature of CA 125 found in apparently healthy women differs from that found in patients with ovarian cancer and that CA 130 epitopes are not present. CONCLUSIONS: Measurement of serum CA 130 concentrations may be useful for excluding women with falsely elevated CA 125 values.

Acrylic Resins

Chemical contrast in X-ray microscopy and spatially resolved XANES spectroscopy of organic specimens.

The scanning transmission x-ray microscope at the National Synchrotron Light Source has been used to record x-ray absorption near-edge structure (XANES) spectra from 0.01-square-micrometer regions of organic specimens. The spectral features observed reflect the molecular structure of the dominant absorbing atoms and provide the contrast mechanism for high-resolution imaging with chemical sensitivity. This technique was used with x-ray energies near the carbon K absorption edge to identify and map separate phases in various polymer blends and to map the DNA distribution in chromosomes with a spatial resolution of 55 nanometers.

Acrylic Resins