PubMed · 3311276

Fluid absorption during urological endoscopy.

Abstract

Transurethral prostatectomy (TURP) and, more recently, percutaneous nephrolithotomy and endoureteric procedures for stones in the kidney and ureter have justifiably become popular because of the many advantages offered by these less invasive procedures. Any surgical operation has its attendant complications and absorption of irrigant fluid is a major and potentially fatal complication of all of these endoscopic techniques. This review examines the incidence, the causes and the pathological sequelae of excessive fluid absorption and suggests some ways to prevent it.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P N Rao. 1987. Fluid absorption during urological endoscopy.. https://doi.org/10.1111/j.1464-410x.1987.tb04940.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A study of the efficiency of polybutadiene-coated zirconia as a reversed-phase chromatographic support.

This work describes the dynamic characteristics of columns packed with polybutadiene (PBD)-coated zirconia. Reduced plate height (h) vs reduced velocity (v) data for alkylbenzenes were acquired for three phases coated with different amounts of PBD. Additional data for benzene (k' = 0) on uncoated and four coated phases were also collected. These h vs v plots have a minimum between 4 and 5, indicating good but not excellent column efficiency. By fitting the Knox equation to these data, the A (packing quality), B (axial diffusion), and C (mass transfer resistance) coefficients were determined. The A coefficients were about 2 in all cases, and the B coefficients had values between 2 and 3. The C coefficients varied from 0.05 to 0.2, depending on the polymer load. The data suggest that the quality of packing and the efficiency of mass transfer resistance in the "film" of polymeric stationary phase, not the stagnant mobile phase, are key to further improvements in column performance. The amount of polymer loaded significantly affects the efficiency through the mass transfer resistance in the stationary phase.

Absorption

Representing primary electrophoretic data in the 1/time domain: comparison to representations in the time domain.

A plot of absorbance vs 1/time (the "1/time domain") is a more useful representation of the primary data in capillary electrophoresis than traditional plots of absorbance vs time (the "time domain") in a wide set of circumstances, especially when comparing electropherograms in which the rate of electroosmotic flow is not precisely the same. The quantity that is of fundamental interest in capillary electrophoresis (CE) is the electrophoretic mobility of an analyte. The electrophoretic mobility of a species is nonlinearly proportional to time and, therefore, not linearly represented in the time domain: that is, the distance between two peaks along the time axis is not linearly related to the difference in their electrophoretic mobilities. In contrast, the electrophoretic mobility is linearly proportional to 1/time, and the distance between two peaks along the 1/time axis is linearly related to the difference in electrophoretic mobilities. Plots in the 1/time domain are similar to the familiar plots in the time domain (each analyte is represented by a peak, and the order of peaks corresponds to the order in which these analytes reach the detector), but the spacing between the peaks corresponds linearly to differences in mobility. This article derives this useful, visually appealing, and broadly applicable plotting strategy and illustrates common situations in which these plots are more useful than plots in the time domain.

Absorption

The future of dental amalgam: a review of the literature. Part 3: Mercury exposure from amalgam restorations in dental patients.

This is the third article in a series of seven on the future of dental amalgam and covers mercury exposure from functioning dental amalgam restorations in patients. It firstly discusses the evidence for mercury release from amalgam fillings by considering the mechanisms of mercury release and its measurement in the expired air and the intra-oral air. In this connection it also discusses the various factors involved in the accurate measurement and calculation of mercury levels in these situations. It finally describes the various attempts to calculate the daily mercury dose from dental amalgam fillings and considers the likely accuracy of these calculations.

Absorption