Retinal wholemounts: a simple method for precise mapping.

Abstract

A simple and inexpensive method to analyse retinal wholemounts is described. It allows the definition of regularly spaced sites to map regional specializations of the retina under light microscopy. After attaching a piece of translucent millimetre graph paper behind the slide holding the preparation, the two grid patterns of the graph paper and of the eye-piece grid are used in combination for the definition of sites for analysis and the return to specific areas as small as 50-100 microns2. The present method is simpler and offers several advantages when compared to others based on X-Y movements of the microscope stage or on photographic montage.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P P Giorgi, M L Graydon. 1987. Retinal wholemounts: a simple method for precise mapping.. https://doi.org/10.1016/0165-0270(87)90005-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Transjugular intrahepatic portosystemic stent shunt (TIPSS) with use of Rösch-Uchida transjugular liver access set--evaluation by CT and its clinical application].

Appropriateness of the Rösch-Uchida transjugular liver access set designed for TIPSS procedure was confirmed, especially about the catheter angle and effective length of the 20 G puncture needle, by CT analysis on three dimensional vascular anatomy of the liver. Clinically, TIPSS using the set was successfully made for two patients, connecting superior right hepatic vein with right portal vein in one patient and middle hepatic vein with left portal vein in another patient with hypoplastic right portal vein. Prior to TIPSS procedure, verification of vascular anatomy on CT images is the key to success of TIPSS in safe.

Evaluation Studies as Topic

[Testing an ultrasonic scanner for determination of urinary bladder volume].

Bladderscan BVI 2000 is a portable ultrasound scanner, specially constructed for determination of bladder volume. We have tested this scanner for accuracy, systematic errors and the training required to use it. The bladder volumes measured by ultrasound scanning were compared with the true volumes. Fifty-six measurements were made. We found the accuracy of BVI 2000 sufficient to determine bladder volumes as either small or large. We found no systematic errors. No special training is required to use the scanner. The device is thus useful in most clinical situations when greater accuracy than indicated here is not necessary.

Evaluation Studies as Topic