[Basic parameters and testing methods for medical roentgen screens].

Abstract

The basic parameters characterizing the optical properties of the roentgen screens of all types included in the CMEA Standards and GOSTs have been considered. The classification of screens is given. The measurement principles for the absolute and relative characteristics of their effectiveness are described. The properties of the screens determining their effect on the image quality such as the definition of the picture, the graininess and the minimal size of observed details have been considered. The methods of controlling the persistence of the screens and the presence of radionuclide tracks have been described.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A M Gurvich, M A Il'ina, R V Katomina. [Basic parameters and testing methods for medical roentgen screens].. https://pubmed.ncbi.nlm.nih.gov/3326993/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Performance comparison of an active matrix flat panel imager, computed radiography system, and a screen-film system at four standard radiation qualities.

Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.

Radiographic Image Enhancement↗