PubMed HealthSearch

PubMed · 3328811

High-speed high-resolution ultrasonography.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Singh, S N Tandon, H M Gupta. 1987. High-speed high-resolution ultrasonography.. https://doi.org/10.1007/bf02441755

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A little to a lot or a lot to a little: is NTCP always minimized in multiport therapy?

PURPOSE: We address the question of whether or not, for the same average (or integral) dose, a smaller uniform dose to an entire normal tissue structure always results in a lower normal tissue complication probability (NTCP) than does a proportionally larger dose to a partial volume of the same structure. METHODS AND MATERIALS: A recent compilation of NTCP data and two theoretical formulations of the dependence of NTCP on dose and partial volume irradiated-the Lyman probit equation and the binomial model-are used to examine this question. Both models fit equally well available NTCP data. RESULTS: Empirical data indicate that for lung, kidney, and possibly liver (but not for esophagus, brain, or heart), given a fixed tumor dose and fixed integral dose, NTCP can be minimized by irradiating a partial volume fraction rather than the entire normal organ. The binomial model supports this interpretation, whereas the probit model predicts that for all organs uniform irradiation of the whole organ always results in the lowest possible NTCP. CONCLUSIONS: In contrast to what is commonly believed, this study suggests that for at least two normal tissues, namely lung and kidney, there may be situations where "a lot to a little" (i.e., fewer treatment ports) will result in higher tumor control probability and better treatment plan than "a little to a lot" (i.e., multifield treatment). This finding, which is independent of the binomial or probit models used here, depends only on the accuracy of the empirical NTCP data. It is also interesting to note that: a) lung and kidney are commonly classified as parallel tissues, while the others have more of a serial architecture; and b) the choice of the NTCP model can have a profound impact on treatment planning decisions.

Models, Theoretical

An all-atom distance-dependent conditional probability discriminatory function for protein structure prediction.

We present a formalism to compute the probability of an amino acid sequence conformation being native-like, given a set of pairwise atom-atom distances. The formalism is used to derive three discriminatory functions with different types of representations for the atom-atom contacts observed in a database of protein structures. These functions include two virtual atom representations and one all-heavy atom representation. When applied to six different decoy sets containing a range of correct and incorrect conformations of amino acid sequences, the all-atom distance-dependent discriminatory function is able to identify correct from incorrect more often than the discriminatory functions using approximate representations. We illustrate the importance of using a detailed atomic description for obtaining the most accurate discrimination, and the necessity for testing discriminatory functions against a wide variety of decoys. The discriminatory function is also shown to be capable of capturing the fine details of atom-atom preferences. These results suggest that the all-atom distance-dependent discriminatory function will be useful for protein structure prediction and model refinement.

Models, Theoretical

Configuration options for intensity-modulated radiation therapy using multiple static fields shaped by a multileaf collimator.

One-dimensional (1D) intensity-modulated beams (IMBs) can be generated by multiple static fields (MSFs) created by a multileaf collimator (MLC) with the radiation switched off between field re-settings (Bortfeld-Boyer method). Each component irradiation is of equal fluence. This paper presents and analyses the formulae for the number of physically allowed combinations of leaf settings which generate any given IMB. The formulae are general to an IMB with any number of local minima and extend from the well-known N! formula for a single-peaked IMB with N left-leaf (L-leaf) and N right-leaf (R-leaf) positions. A 'combination' is a set of N L-leaf and R-leaf pairings. A 'physically allowed combination' is one in which no L-leaf is paired with an R-leaf to its left. The physically allowed combinations are grouped by specific properties into classes in which the well-known techniques of 'leaf-sweep' and 'close-in' are just two members. Consideration of these properties leads to a new suggestion of the 'forced-baseline' configuration in which the first intensity increment is delivered for the full field width and there remain choices concerning the delivery of the rest of the IMB within which two different possibilities are 'one-out-of-sync leaf-sweep' and 'minimum leaf travel'. The extension to 2D is briefly introduced.

Models, Theoretical