PubMed Health⌕ Search

PubMed · 3333398

Thermedics' approach to ventricular support systems.

Abstract

Temporary and permanent ventricular assist systems, developed by Thermedics, Inc., are described, including rationale, design, operation and surgical applications. Clinical data are presented for pneumatically driven temporary left ventricular assist devices (LVAD). Usefulness of this device rests on the assumption that tissue of a weakened heart can recover if relieved for a time by an LVAD. The surgical implantation of an LVAD is reported in a case where the patient later received a heart transplant. The concept and technology of the subsystems of a permanent ventricular assist system (VAS), now ready for preclinical trials, are discussed. Design of a low-speed, torque-motor driven blood pump is described. Details are presented on transcutaneous energy transmission by means of a transformer, one of whose coils is embedded under the skin. Though less efficient than percutaneous transmission, the method eliminates infection risk. Special types of polyurethanes are analyzed in respect to their biocompatibility. It is concluded that flocking of the polyurethane surface allows the growth of a biological lining which is highly antithrombogenic. Sintered metal powders are found to be most efficient for fabrication of rigid pump components. A lenticular pump design is proposed to solve the problem of pressure differentials in the sealed device. Cardiac endocrine functions are cited in support of using assist devices that leave the heart in place.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Szycher, W Clay, D Gernes, C Sherman. 1986. Thermedics' approach to ventricular support systems.. https://doi.org/10.1177/088532828600100103

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Percutaneous endocardial and epicardial ablation of hypotensive ventricular tachycardia with percutaneous left ventricular assist in the electrophysiology laboratory.

Ventricular tachycardia (VT) in the setting of structural heart disease is challenging to treat with percutaneous catheter ablation due to the presence of complex substrate, multiple morphologies, hemodynamic instability, and epicardial circuits. When substrate-based approaches fail, however, it may be impossible to map and ablate hemodynamically unstable arrhythmias. We describe a novel approach to endocardial and epicardial mapping and ablation of hypotensive VT using a percutaneous left ventricular assist device in the electrophysiology laboratory, permitting near-surgical access to cardiac structures.

Assisted Circulation↗

IgG classification of anti-PF4/heparin antibodies to identify patients with heparin-induced thrombocytopenia during mechanical circulatory support.

Commercial immunoassays frequently detect anti-PF4/heparin antibodies during mechanical circulatory support (MCS), but only a small minority of patients develops heparin-induced thrombocytopenia (HIT). Whereas platelet functional tests can distinguish between platelet-activating and non-platelet-activating antibodies, commercial PF4-dependent immunoassays do not. Between 2003 and 2004, 113 patients were placed on MCS. Blood samples were obtained on postimplant day 5-7 for analyses by antibody assays and the functional heparin-induced platelet activation (HIPA) assay. Three distinct groups of patient sera were identified: platelet-activating anti-PF4/heparin antibodies (n = 10), non-platelet-activating anti-PF4/heparin antibodies (n = 53), and anti-PF4/heparin antibody negative (n = 50). Patients with platelet-activating antibodies had the highest risk for thromboembolic events (P < 0.005), whereas those with non-platelet-activating antibodies did not differ from antibody negative patients (P = 0.369). The enzyme-immunoassay and column agglutination assays, which cover all immunoglobulin classes, demonstrated adequate sensitivity and negative predictive value; yet, both lacked specificity with respect to the platelet-activating antibodies. If all antibody positive patients were further classified by an IgG-specific anti-PF4/heparin enzyme-immuno assay, specificity for platelet-activating antibodies increased. Whereas IgG-specific optical density (OD) values below 1.0 were likely for non-platelet-activating anti-PF4/heparin antibodies, higher values were progressively predictive for pathogenic platelet activation. The probability of the development of clinical HIT also increased steeply. In conclusion, platelet-activating anti-PF4/heparin antibodies are relatively common (about 9%) in patients on MCS and are associated with significantly higher thrombotic event rates. Low IgG-specific OD values (< 1.0) in the enzyme-immunoassay indicate low likelihood for the presence of platelet-activating antibodies. These results justify further validation so that anticoagulation during MCS becomes safer and adequate.

Assisted Circulation↗