Automation of routine coagulation testing using a random access centrifugal analyzer.

Abstract

The results are reported of a clinical and laboratory evaluation of the use of a random-access centrifugal analyzer linked to a personal computer in the management of the routine workload of a hemostasis laboratory. Over a three-month period, prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin clotting time (TCT), and derived fibrinogen (Fib) were performed on a total of 929 samples. Included in the study were 448 samples from patients receiving anticoagulants (oral anticoagulants, 228; heparin, 166; heparin and warfarin, 130) and 351 samples from patients requiring coagulation screens (PT, APTT, TCT, Fib). Tests were done in parallel with tilt-tube manual techniques and the results correlated. The correlation coefficients were PT, 0.99; TCT, 0.72; APTT, 0.96; Fib, 0.97. Discrepancies were analyzed and were due to hypofibrinogenemia and hyperlipidemia. The poorer correlation coefficient of TCT was attributable both to lower reproducibility of the manual test and the effect of dysfibrinogenemia or FDPs in liver disease. In no case was an abnormality or diagnosis missed using the centrifugal analyzer. In several cases the increased sensitivity of the analyzer improved the detection of the lupus anticoagulant. The use of automation was accompanied by a major reduction in workload and reagent costs. The machine has been used to assay a wide range of coagulation tests by clot based and chromogenic substrate methods. In conclusion, a programmed centrifugal analyzer is a safe, efficient, and flexible way of automating routine coagulation tests. It widens the reportoire of tests performed in the Hemostasis laboratory by using a machine capable of being used in other areas of pathology.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Rowell, M J Elms, J Young, I H Bunce. 1988. Automation of routine coagulation testing using a random access centrifugal analyzer.. https://doi.org/10.1093/ajcp%2F89.3.347

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

In vitro kinetics of factor VIII activity in patients with mild haemophilia A and a discrepancy between one-stage and two-stage factor VIII assay results.

In some mild haemophilia A patients (discrepant haemophilia), factor VIII coagulant activity (FVIII:C) levels, by one-stage assay are more than double than those by two-stage assay. This may be due to the longer incubation times (10-12 min) in the two-stage assay. This study aimed to determine the time course of the activation phase of the two-stage assay, using both classical coagulation and chromogenic detection methods. In both systems, for equivalent patients (equivalent FVIII:C levels by one-stage and two-stage assays, n = 6, all different mutations), similar FVIII:C results were obtained with short- or long-incubation times. In contrast, plasma from discrepant patients (n = 8, five different mutations) showed higher FVIII:C at shorter incubation times than after longer incubation times. In the chromogenic assay, FVIII:C levels were higher after incubation for 2 min (23-56%, mean 41%) than after 10 min (19-41%, mean 29%). In the classical coagulation assay, FVIII:C levels were higher at shorter incubation times (21-64%, mean 37%) than with the longer incubation times usually used (13-29%, mean 23%). These time-course experiments have verified that the longer incubation time used in the two-stage assay is at least partly responsible for the lower FVIII:C measured by that assay in discrepant haemophilia.

Blood Coagulation Tests↗

Von Willebrand disease within the collective of haemophilic patients as reason for unexpected bleeding episodes.

In the treatment of haemophilia A and B, recombinant coagulation factors are increasingly replacing plasma-derived factor VIII and IX concentrates. Although provided with replacement therapy, individual patients may exhibit bleeding episodes, which are difficult to control. These bleeds may be caused by von Willebrand disease (VWD) as an additional underlying coagulation disorder. We report in the present study our experience that in the collective of haemophilic patients, VWD must be anticipated at least with the same order of magnitude as it appears in a normal healthy population. Among the patients at our treatment centre, two patients (1.5%) were identified as suffering from VWD in addition to haemophilia A. In the collective of haemophilia B patients at our centre, three patients (10%) with VWD were found. Two of these patients exhibited unexpected severe bleeding episodes, which could only satisfactorily be controlled by the administration of Haemate-P or DDAVP supplementary to the recombinant coagulation factor concentrate.

Blood Coagulation Tests↗