PubMed HealthSearch

PubMed · 3382133

Hydroxyapatite coatings.

Abstract

Four coating techniques were evaluated to determine which is most suitable for producing a dense, highly adherent coating onto metallic and ceramic implant materials. Two of the selected coating methods have serious limitations for use in this particular application, and did not meet the specified criteria for satisfactory coating as defined in the initial stages of the study. For example, the dip coating-sintering technique was judged to be unsatisfactory because of the adverse effect of the high-temperature sintering cycle on the mechanical properties of the metallic substrate materials. These materials could not be used in load-bearing applications because of the excessive grain growth and loss of the wrought structure of both the commercially pure Ti and Ti-6Al-4V substrates, and the loss of ductility in the cast Co-Cr-Mo alloy. Another area of concern was that bond strength between the HA coating and the substrate was not high enough to insure that interfacial failure would not occur during the lifetime of the implant. The immersion-coating technique, in which the metal substrate is immersed into the molten ceramic, was shown in a previous study to be the best method of coating a bioreactive glass onto a Co-Cr-Mo implant. Heating HA above its melting temperature, however, caused undesired compositional and structural changes, and upon solidification very limited adherence between the modified ceramic and substrate material occurred under the conditions of this study. The HIP technique, in which the Ti powder substrate and the HA powder coating are sintered together in a high-pressure autoclave, shows great promise for the fabrication of high-quality composite implants. Initial studies have indicated that high-density Ti substrates with a small grain size that are well bonded to a dense HA coating can be produced under optimum conditions. Sintering and densification additives, such as SiO2 powder, do not appear to be necessary. The main drawback to this technique appears to be the reaction of the encapsulating material--whether soda glass, steel, or fused silica--to the HA coating. More extensive testing will necessary to determine the ideal conditions for the HIP technique, as efforts on this technique were discontinued in order to concentrate on the HIP technique, as efforts on this technique were discontinued in order to concentrate on the optimization of the sputter-coating technique so that coated implants for an animal study could be produced on schedule. Based on the results of this study, sputter coating appears to be the method of choice for forming a dense, adherent coating of HA onto a metal substrate.(ABSTRACT TRUNCATED AT 400 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W R Lacefield. 1988. Hydroxyapatite coatings.. https://doi.org/10.1111/j.1749-6632.1988.tb38501.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The metabolic dependency of retinal adhesion in rabbit and primate.

OBJECTIVE: To determine the oxygen and glucose dependency of retinal adhesion in primate and rabbit. METHODS: Experiments were performed on Dutch rabbits and monkeys. Retinal adhesiveness was measured by peeling the retina from the retinal pigment epithelium in vitro, under different conditions of PO2 and glucose supply, and by observing the amount of adherent pigment. In vivo ischemia was produced by raising the intraocular pressure. RESULTS: Retinal adhesion failed quickly at low oxygen tensions, but a well-oxygenated solution preserved strong retinal adhesion in vitro for 15 to 20 minutes in rabbit tissue and up to 50 minutes in primate tissue. Ischemic adhesive failure was reversible on raising the PO2. Glucose levels did not affect adhesiveness. Ischemia in vivo for more than 1 minute caused rabbit retina to lose its adhesiveness. CONCLUSIONS: Retinal adhesion is continually and reversibly dependent on oxygenation, and probably on aerobic metabolism. Primate tissue is more resistant to metabolic adhesive failure than is rabbit tissue, but the metabolic requirements appear qualitatively similar.

Adhesiveness

An autologous fibrin tissue adhesive with greater bonding power.

OBJECTIVE: To describe and evaluate an autologous fibrin tissue adhesive (AFTA) that uses a combination of ethanol and freezing to precipitate fibrinogen (AFTA-E). DESIGN: The bonding power of AFTA-E was compared with that of a conventional AFTA based on ammonium sulfate precipitation of fibrinogen (AFTA-A). In this study, Silastic, porcine dermis, and human dura mater blocks were bonded together for 10 and 30 minutes with AFTA-E or AFTA-A. The blocks were then separated and the bonding power was measured. The efficacy of AFTA-E was also evaluated after a 24-hour refrigeration. SETTING: The Department of Otolaryngology Research Laboratory at the University of Illinois Eye and Ear Infirmary, Chicago, Ill. PARTICIPANTS: Blood was drawn from 86 healthy volunteers and AFTA-E and/or AFTA-A was manufactured. RESULTS: The AFTA-E was shown statistically to bond stronger than the AFTA-A. In addition, it was found that the efficacy of AFTA-E was unchanged after a 24-hour refrigeration. CONCLUSIONS: The improved AFTA, AFTA-E, is a superior alternative to the conventional AFTA-A. Furthermore, AFTA-E can be manufactured before surgery and stored, thus minimizing preparation time during surgery.

Adhesiveness

Effects of a structural change in collagen upon binding to conditioned dentin studied by 13C NMR.

To develop a better adhesive functional monomer, it is imperative to understand the adhesion mechanisms of the resin to the dentin surface. Bond strength to the decalcified dentin surface pretreated with dentin primer, an aqueous ethanol solution of N-methacryloyl glycine, increases by increasing the water content in the primer. The aqueous primer could increase the thickness of the hybrid layer. The structural change of dentinal collagen with NM alpha A was studied by using a model compound for collagen,--(1Pro-2Pro-3Gly)10--, by 13C nuclear magnetic resonance (NMR). The model compound was aggregated in ethanol but dissociated in water. It was found that NM alpha A effectively dissociated the aggregated model compound in water. The dissociation of decalcified dentin was essential to create a thick hybrid layer that could afford a higher bond strength to dentin.

Adhesiveness