Abstract

Totally implantable drug delivery devices have been shown to be safe and effective in the delivery of drugs both systemically and regionally. Applications have been developed for continuous infusions of drugs and are currently being developed for variable flow rates with more sophisticated programmable pumps. Some of the potential benefits of such devices include improved drug efficacy with reduced systemic toxicities, more controlled dosing of drugs, improved quality of life, delivery of proteins and peptides, and individualized patient dosing. The potential exists for creating biofeedback closed loop therapies for diabetes, cardiovascular diseases, and some central nervous system diseases in the future.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Johnston, S Reich, A Bailey, J Sluetz. 1988. Shiley INFUSAID Pump technology.. https://doi.org/10.1111/j.1749-6632.1988.tb31812.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optical integrating balloon device for photodynamic therapy.

BACKGROUND AND OBJECTIVES: It is difficult to deliver light uniformly and efficiently over the complex shapes presented by various organs for photodynamic therapy (PDT). A balloon delivery device for photodynamic therapy was designed and tested for treatment of various anatomic tissues. The device uses the principle of optical integration by multiple internal diffuse reflections to achieve uniform output illumination. STUDY DESIGN/MATERIALS AND METHODS: Soft, white, medical-grade silicone balloons were made in various shapes and tested for optical output, uniformity, efficiency, and power capabilities. Balloons were cast to be approximately the shape of the target tissue surface, organ, or cavity. Laser power was introduced into the saline-filled balloon by one or more fiber optics. Devices were constructed and used to illuminate oral mucosa and uterine endometrium for PDT. RESULTS: The balloon walls had low optical absorption, high diffuse reflectivity (80-95%), and low diffuse transmittance (5-20%) in the 500- to 900-nm wavelength region. Optical efficiencies of 65% were typical with emitted light over complex, nonspherical surfaces. Efficiency increased with inflation of the device, such that irradiance (power/area) at the balloon surface was nearly constant with inflation. CONCLUSION: Optically integrating balloons can provide highly uniform, efficient light exposure over complex tissue surfaces. Uniformity and irradiance were not strongly affected by balloon inflation, and these robust devices are easy to produce in essentially any shape.

Catheterization

Sonographic diagnosis of subcapsular liver hematoma mimicking tumor in a neonate.

Subcapsular hematomas of the liver in neonates uncommonly present as an abdominal mass without clinical signs of bleeding. We report a case in which sonography 10 days after birth demonstrated 2 large hepatic lesions that were initially considered to be tumors. The diagnosis of subcapsular liver hematoma was es tablished by serial ultrasound examinations, which demonstrated rapid diminution of the lesions. A history of difficult umbilical venous catheter insertion was then obtained retrospectively.

Catheterization