PubMed HealthSearch

PubMed · 3393863

Sentinel event notification system for occupational risks.

Abstract

Mandates for provider reporting systems have existed in a number of states for many years, but due to various shortcomings the potential for targeted surveillance of occupational illness and injury has not been realized. To achieve a more uniform, active approach to provider reporting, SENSOR will be created as a cooperative state-federal effort designed to develop local capability for the recognition, reporting, follow-up, and prevention of selected occupational disorders. To demonstrate the feasibility of this approach, NIOSH funded a small number of SENSOR projects in 1987. Ultimately, joint state-federal support will be essential to maintain SENSOR activity within a state. SENSOR should not be viewed as the sole approach to the surveillance of occupational illness and injury. Other approaches to the identification of cases of occupational illness or injury and to monitoring the trends of occurrence of these disorders have been developed by NIOSH and various states, and they will continue to function.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E L Baker. 1988. Sentinel event notification system for occupational risks.. https://pubmed.ncbi.nlm.nih.gov/3393863/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Transjugular intrahepatic portosystemic stent shunt (TIPSS) with use of Rösch-Uchida transjugular liver access set--evaluation by CT and its clinical application].

Appropriateness of the Rösch-Uchida transjugular liver access set designed for TIPSS procedure was confirmed, especially about the catheter angle and effective length of the 20 G puncture needle, by CT analysis on three dimensional vascular anatomy of the liver. Clinically, TIPSS using the set was successfully made for two patients, connecting superior right hepatic vein with right portal vein in one patient and middle hepatic vein with left portal vein in another patient with hypoplastic right portal vein. Prior to TIPSS procedure, verification of vascular anatomy on CT images is the key to success of TIPSS in safe.

Evaluation Studies as Topic

[Testing an ultrasonic scanner for determination of urinary bladder volume].

Bladderscan BVI 2000 is a portable ultrasound scanner, specially constructed for determination of bladder volume. We have tested this scanner for accuracy, systematic errors and the training required to use it. The bladder volumes measured by ultrasound scanning were compared with the true volumes. Fifty-six measurements were made. We found the accuracy of BVI 2000 sufficient to determine bladder volumes as either small or large. We found no systematic errors. No special training is required to use the scanner. The device is thus useful in most clinical situations when greater accuracy than indicated here is not necessary.

Evaluation Studies as Topic