Anterior rests for maxillary removable partial dentures.

Abstract

Positive anterior rests were shown to be an essential element of design when considering stress distribution with a removable partial denture involving anterior teeth. Proximal plates often added stability and reduced stress accumulation in any one region. Distobuccal forces on the extension base adversely affected the primary canine abutment. Forces in the regions of the anterior base and central incisor abutment produced the most widespread transmission of stress throughout the arch. Greater stress throughout the arch was observed when forces were applied to the central incisor rather than to the right canine abutment. There is a need for established criteria of rest form and placement. Guidelines for using the natural crown as opposed to a positive rest seat in a restoration are needed. Continuing studies of other anterior rest forms should increasingly clarify this phase of treatment planning. The dentist should recognize the need for structural integrity in the anterior maxillary segment when designing removable partial dentures. A practical, defensible rationale for the routine use of maxillary anterior teeth as removable partial denture abutments must be established.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Berg, A A Caputo. 1978. Anterior rests for maxillary removable partial dentures.. https://doi.org/10.1016/s0022-3913(78)80010-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of attachment wear on retention of mandibular overdenture.

UNLABELLED: The aims of this study were: (i) to evaluate and compare retention of two-teeth (implant) supported mandibular overdenture with either stud or magnetic attachments during linear (axial) and rotational (paraxial) dislodgements; (ii) to compare retentive properties before and after wear simulation. The test group consisted of five magnetic and four stud overdenture attachments (n = 12 specimens for each attachment type). Retention in axial direction was evaluated on one-tooth (implant) model by measuring maximum retentive force (N) and range of retention (mm) during the linear dislodgement. Retention in the paraxial direction was evaluated on mandibular-overdenture model by measuring the maximum retentive force (N) during three types of rotational dislodgements - anterior, lateral and posterior. The minimum number of cycles required to simulate wear was determined by special wear test. Afterwards, the wear was simulated in the test group, and retention in axial and paraxial directions was measured again. STATISTICAL ANALYSIS: one-way anova, Scheffe post hoc and paired-samples t-tests (P < 0.05). Initially, studs had higher retention (4-11 N) than magnets (4.5-6 N) in axial direction. After the wear simulation, it had decreased from 76% to 48% for some of the studs and had become similar to the retention of magnetic attachments. Magnets had lower retention range (0.2-0.3 mm) than studs (0.5-1.1 mm). Studs provided similar or higher retention in paraxial directions than magnetic attachments both before and after wear simulation. Retentive properties of magnets decreased mostly with posterior rotational dislodgement. Retentive properties of stud overdenture attachments were less constant.

Dental Abutments↗

Transitioning patients from teeth to implants.

One major obstacle to treatment with implants is the transitional phase between a tooth supported occlusion and an implant supported occlusion. This is of particular concern when a patient with a failing dentition has not worn a removable prosthesis before and is planning to have a reconstruction supported by implants.

Dental Abutments↗

Impression techniques for implant dentistry.

The object of making an impression in implant dentistry is to accurately relate an analogue of the implant or implant abutment to the other structures in the dental arch. This is affected by use of an impression coping which is attached to the implant or implant abutment. This impression coping is incorporated in an impression - much as a metal framework is 'picked up' in a remount impression for fixed prosthodontics. With implant copings the coping is usually attached to the implant or abutment with screws. The impression material used is usually an elastomeric impression material; the two types most widely used and shown to be the most appropriate are polyether and polyvinyl siloxane impression materials.

Dental Abutments↗