PubMed HealthSearch

PubMed · 3407042

Flexible cystoscopy.

Abstract

Flexible fiberoptic technology was first applied to cystoscopy in 1973, with greatly increased usage since 1982. Most procedures formerly performed with rigid cystoscopes can be done using flexible cystoscopes with minimal or no anesthesia. Patient positioning and precystocopy preparation and draping are simplified with the flexible fiberoptic instruments. Complete examination of the urethra and bladder can be performed with a single-lens system and with the patient in a variety of positions. Fiberoptic cystoscopy is limited in patients who are bleeding or have blood clots in their bladders. Withdrawal of irrigant or bladder drainage is cumbersome, and the fiberoptic image is currently not of the same caliber as that of the rigid-lens systems. Fiberoptic cystoscopy has become the procedure of choice for many urologists for ureteral stenting prior to extracorporeal shock-wave lithotripsy. With the advent of lithotripters that require no anesthesia, this application is likely to broaden. Future applications of flexible cystoscopy may include a flexible videocystoscope for use in diagnostic and therapeutic procedures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T J Kennedy, G M Preminger. 1988. Flexible cystoscopy.. https://pubmed.ncbi.nlm.nih.gov/3407042/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Endoscope modifications for laser prostatectomy.

Prior to the development of the technique of laser prostatectomy, contemporary modifications to resectoscope design for transurethral prostatectomy had been scant. With the introduction of laser prostatectomy and the characterization of the "mini-TURP" technique, a new demand for improved continuous-flow cystoscopes and resectoscopes has developed. The ideal cystoscope design for laser prostatectomy would require the following: (1) continuous irrigant flow for optimum cooling of the laser element; (2) a large inflow port so that flow is not impaired by the presence of the fiber in the working channel; (3) a large outflow port to maximize irrigant flow; and (4) a fiber stabilizer to enable easy manipulation of the fiber in the center of the viewing field. The ideal resectoscope design for laser prostatectomy would require the following: (1) continuous flow of irrigant for cooling of the laser fiber; (2) stabilization of the laser fiber in the center of the field of view; (3) the ability to interchange electrocautery loops with laser fibers without changing the sheath; and (4) the ability to apply laser energy to tissue with the same Iglesias action used in transurethral resection of the prostate (TURP). This review analyzes the features of the new continuous-flow cystoscopes and resectoscopes manufactured specifically for use in laser prostatectomy. All manufacturers were requested to submit their most up-to-date literature and photographs of the specific instruments they manufacture. The technical specifications, advantages, and disadvantages of each instrument are discussed.

Cystoscopes