PubMed HealthSearch

PubMed · 3414022

Fusional limits for a large random-dot stereogram.

Abstract

Fusional limits of absolute retinal disparity between the two half-images of a large random-dot stereogram have been measured. The stereogram was viewed with disparity clamped at selected values (vergence loop opened), but without stabilization against conjugate eye movements, allowing the subject to look freely to different parts of the stereogram. Movements of both eyes were measured with a scleral coil technique. Limits for acquisition and retention of fusion were similar for the large stereogram. Total fusional ranges between 128 and 175 min arc were found in the different subjects. Limits for acquisition of fusion were smaller when fusion was preceded by prolonged stimulation with a large disparity (exceeding the fusional range) of the same direction (crossed or uncrossed). Thus, hysteresis between acquisition and retention was absent and the hysteresis present between loss of fusion and refusion was due to a reduction of the refusional limit. Probably this reduction is related to the recent history of binocular rivalry. Inspection of ocular vergence movements made during stimulation with constant or slowly changing disparity shows that neural remapping of retinal correspondence is rather unlikely.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C J Erkelens. 1988. Fusional limits for a large random-dot stereogram.. https://doi.org/10.1016/0042-6989(88)90163-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Rotation of Listing's plane during vergence.

When visually fixating targets on an isovergence surface, the position of each eye was constrained to a plane. Thus, Listing's law holds during vergence. The planes were, however, rotated temporally with respect to those when viewing distant targets. The effect of this rotation was to produce a torsion which depended on eye elevation; extorsion of the two eyes for downward gaze and intorsion for upward gaze. The saccadic velocity command was relatively unaffected during vergence. Computer simulations suggest that the saccadic tonic command and the vergence command interact multiplicatively in three dimensions.

Convergence, Ocular

[Congenital nystagmus and intermittent exotropia. Suppression of nystagmus by fusional convergence].

We report on a patient with a combination of congenital nystagmus and intermittent exotropia. When the exotropia became manifest, a gross nystagmus appeared. When, however, the exotropia was overcome by fusinal convergence, the nystagmus was largely suppressed. The angle of squint was surgically reduced by such an amount that the exodeviation was just compensated, and the fusional convergence required to overcome the remaining angle sufficed to suppress the nystagmus.

Convergence, Ocular

[Comparison of five methods for subjective assessment of ocular cyclodeviation].

METHODS: 1. simple Maddox rod (Franceschetti) 2. set of scaled large diameter Maddox rods 3. synoptophore 4. synoptometer (Cüppers) 5. dark red glass in front of the Harms tangent scale (Kolling). Whereas the first two methods allow to measure in primary position only, the other three also permit secondary and tertiary position measurements. Thirty normal subjects underwent comparative measurements by means of the above techniques in monocular and binocular condition. The median values indicate that all these methods are reliable but that certain specific differences influence the results. For this reason, pre- and postoperative measurements of ocular torsion should always be performed by the same method. The most appropriate techniques have shown to be: the set of scaled Maddox rods for measurements in primary position only, the dark red glass in front of the Harms tangent screen for measuring also in secondary and tertiary positions.

Convergence, Ocular