PubMed Health⌕ Search

PubMed · 3418476

Peritoneal drainage for necrotizing enterocolitis.

Abstract

This study evaluates the role of primary peritoneal drainage (PPD) in the management of neonatal necrotizing enterocolitis (NEC). Of 169 patients with definite NEC, 92 (55%) underwent operation: primary laparotomy, 41 patients (45%); and PPD, 51 patients (55%). Seventeen (33%) of the PPD infants had subsequent laparotomy within seven days. Pneumoperitoneum was the indication for operation in 37% of the primary laparotomy and 67% of the PPD infants. Following PPD, 34 patients (67%) showed clinical improvement. Operative survivals were as follows: primary laparotomy, 83%; PPD, 53%. Infants who had PPD had a significantly lower mean birth weight, gestational age, preoperative pH and platelet count, and a significantly higher incidence of intraventricular hemorrhage and patent ductus arteriosus. For infants weighing less than 1,000 g at birth, the survival was similar following primary laparotomy (57%) and PPD (52%); this occurred in spite of the higher incidence of adverse risk factors in the PPD infants. For infants weighing greater than 1,000 g, the survival was 86% following primary laparotomy and 62% after PPD; in this group, all the early deaths following PPD occurred in critically ill infants who died within 48 hours of drainage. The late survival rates were as follows: primary laparotomy, 76%; PPD, 35%. More than half of the late deaths following PPD were not related to NEC, reflecting the difference between the two patient populations. Primary peritoneal drainage is a useful adjunct to resuscitation of the critically ill infant with complicated NEC, particularly prematures less than 1,000 g birth weight with intestinal perforation. Primary peritoneal drainage is not an alternative to laparotomy, which is recommended when an optimal clinical response has been achieved.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H W Cheu, K Sukarochana, D A Lloyd. 1988. Peritoneal drainage for necrotizing enterocolitis.. https://doi.org/10.1016/s0022-3468(88)80368-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional Foley drainage systems--do they drain the bladder?

PURPOSE: Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. MATERIALS AND METHODS: Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. RESULTS: A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. CONCLUSIONS: Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

Drainage↗