Present state and future trends in electrical heart stimulation.

Abstract

Examples of electrical heart stimulation techniques are presented to illustrate for the physician and biomedical engineer the technical feasibility of realizing many therapeutic concepts by means of microelectronics. Because of the life-supporting applications, extremely high system reliabilty must be guaranteed. The usual methods of enhancing safety by providing redundancy cannot be used, and the service life requirements can be met only by appropriate adaptation of the current consumption due to the limited battery capacity. Based on the practical experience gained in the manufacture of more than 100,000 implantable devices, it can be reported that by rigid application of, and adherence to, quality assurance measures reliability values can be achieved of lambda = 10(-7)h-1 at a confidence level of 90% for the hybrid components and of lambda = 10(-9)h-1 for integrated circuits and passive components. The requirement for technical reliability of the implantable device for patient safety requires a thorough understanding of all technical and medical details of the therapeutic device. The success of future developments (e.g. the automatically-controlled systems which are meant to substitute for the multiprogrammable pacemakers) will not only require utilization of currently available technologies but also will depend to a great extent on active participation of the physicians in the development process itself.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Schaldach. 1987. Present state and future trends in electrical heart stimulation.. https://pubmed.ncbi.nlm.nih.gov/3441247/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparing spot electrode arrangements for electric impedance cardiography.

This study investigates whether an arrangement with nine spot electrodes, for thoracic bio-impedance cardiography, can be replaced by an arrangement with five spot electrodes. The study was conducted on 15 healthy subjects, six females and nine males, in supine rest. The variables obtained from the measurements were the mean of the impedance of the thorax segment between the recording electrodes, the maximum negative deflection of the first derivative of the thoracic impedance, the left ventricular ejection time and an estimate of left ventricular stroke volume. An analysis of variance for a randomized complete block design was used to determine whether significant differences exist in the group means of the observed variables between six different electrode arrangements. If no statistically significant differences were found in these group means between pairs of arrangements, Bland and Altman analyses were used to determine the differences in the observed variables between pairs of arrangements for individual subjects. This study concludes that reducing the number of spot electrodes from nine to five, does not yield significant differences in the group means of the observed variables, but it could result in large differences in the values of these variables for individual subjects.

Cardiography, Impedance↗

Are European Resuscitation Council recommendations for paddle force achievable during defibrillation?

Transthoracic impedance (TTI) is an important determinant of success in defibrillation. Low TTI increases transmyocardial current and therefore increases the chance of depolarising a critical mass of myocardium. A major component of TTI occurs at the paddle-skin interface and is minimised by pressure applied to the defibrillation paddles. The International Liaison Committee on Resuscitation (ILCOR) 2000 guidelines recommend that 'firm force' should be applied to both paddles, whereas previous European Resuscitation Council (ERC) 1992 guidelines were more precise, recommending that 12 kg of force should to be applied. We assessed whether defibrillator operators are capable of achieving 12 kg paddle force. Fifty advanced life support-trained doctors and nurses attempted to achieve 12 kg paddle force while simulating defibrillation on a resuscitation doll. The median value of the maximum pressures obtainable was 10.1 (max 16.0; min 5.0) kg force. Only 14% could achieve > or =12 kg force on both paddles for defibrillation. Men achieved more force than women (10.7 vs. 8.1 kg force; P<0.01), and there was a correlation between maximum force achieved and operator height (r2=0.27) and dominant hand-grip strength (r2=0.34). The ERC recommendation of 12 kg paddle force is not achievable by the majority of defibrillator operators.

Cardiography, Impedance↗