PubMed Health⌕ Search

PubMed · 3501982

Artifacts in camera based single photon emission tomography due to time activity variation.

Abstract

Image quality in single photon emission computed tomography (SPECT) using a rotating gamma camera is dependent on the time course of the tracer in the field of view. If acquisition times are slow compared to the tracer turnover, artifacts may occur in the reconstructed images. The properties of such artifacts were studied by computer simulation. Experimental projection data of point sources, cylindrical phantoms, and an anatomically realistic brain phantom were altered by sequentially weighting the projections with a function that varied exponentially or linearly with time. The observed distortion in the reconstructed images could be related to the ratio between the object activity variation and the camera rotation time. If the tracer concentration changed less than a factor of two during one camera rotation then little image distortion was visible although quantitatively the resolution was degraded. If the object's activity variation with time is fast enough to produce noticeable distortion, the artifacts can be reduced by performing multiple, rapid, camera rotations, instead of one rotation, for the same total acquisition time. The proposed procedure is computer storage space intensive and takes longer to produce the transaxial images, but improves image quality.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B D Bok, A N Bice, M Clausen, D F Wong, H N Wagner. 1987. Artifacts in camera based single photon emission tomography due to time activity variation.. https://doi.org/10.1007/bf00281856

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Molecular imaging with new PET tracers].

In the recent years, positron emission tomography (PET) has gained more and more importance, especially in oncology for primary staging, as well as for response evaluation. The glucose analogon (18)F-FDG is the most widely used tracer up to now. In this paper, we review the applications of newly developed, more specific PET tracers. These tracers allow for imaging of a variety of biological processes, such as hypoxia and proliferation. The expression of different receptors can be visualized, like the somatostatin receptor 2 and the integrin alphavbeta3. Moreover, gene expression can be imaged as well. While most of these approaches are currently in the first phases of clinical evaluation, imaging of hypoxia and proliferation might be integrated into the daily routine in the near future.

Image Enhancement↗