PubMed · 3514584
Extended EMIT-DAU phencyclidine screen.
Abstract
In a public hospital emergency room, 580 urines were screened for phencyclidine (PCP) with the routine EMIT-DAU PCP screen, the extended EMIT-DAU PCP screen, and a gas chromatograph/mass spectrometer/computer (GC/MS/COMP) in selected ion mode, which was chosen as the reference method. The extended method produced a 38.5% increase in positives detected over the routine EMIT-DAU PCP screen and allowed 66.4% of the specimens to be signed out as negative without confirmation by GC/MS/COMP. This ability to provide a rapid, relatively inexpensive screen for PCP in urine and, in particular, to eliminate those patients whose specimens are negative, is important in a psychiatric population that contains many acutely psychotic individuals with grossly abnormal behavior.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
F A Ragan, S A Hite, M S Samuels, R E Garey, G Daul, R E Schuler. 1986. Extended EMIT-DAU phencyclidine screen.. https://pubmed.ncbi.nlm.nih.gov/3514584/
Cite the original work for its findings. Save a collection to share your selection of sources.