Mandibular reconstruction. New concepts.

Abstract

The combination of a myocutaneous flap with a three-dimensional bendable reconstruction plate has provided satisfactory results in restoration of mandibular defects following surgical resections in irradiated patients. Twenty-eight patients were treated and prospectively evaluated. Patients requiring postoperative irradiation were excluded from this study. Two groups were identified. Group A (N = 23) required a myocutaneous flap to resurface the soft-tissue defect and group B (N = 5) was treated by primary closure. Seventy-three percent (17 of 23) of patients in group A and 60% (three of five) in group B had received presurgical irradiation but required none after surgery. To date, 64% (18) of the patients have maintained their plates for more than one year, half of these for two years or more. Another 21% (6) have had their plates in place more than six months and the remaining 14% (four) less than six months. One plate was lost in an irradiated group B patient.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P J Gullane, H Holmes. 1986. Mandibular reconstruction. New concepts.. https://doi.org/10.1001/archotol.1986.03780070026006

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stacked plating for metadiaphyseal fractures of the distal radius: a technique report.

Combined injuries of the distal radius and shaft are rare, are usually caused by high energy, and pose a surgical dilemma. Surgical tactics and implants that are routinely used either for isolated fractures of the distal radius or for fractures of the radial shaft are often not applicable for this combined injury. We describe a technique of dual-stacked plating for these metadiaphyseal fractures and its use in two patients.

Bone Plates↗

Plate fixation of olecranon osteotomies.

The management of intra-articular distal humeral fractures remains a difficult surgical problem. Although an olecranon osteotomy provides excellent exposure for management of these fractures, a number of complications can occur after the creation and repair of the osteotomy including nonunion, malunion, hardware failure, and pain secondary to prominent hardware. In an effort to reduce the incidence of these complications, the senior authors now use contoured 3.5 mm reconstruction plates for the fixation of their apex-distal chevron olecranon osteotomies. Two surgeons at a single institution used this technique of exposure on a series of 17 consecutive patients with intra-articular distal humerus fractures between 1996 and 1999. In this series, all osteotomies united. There was one complication related specifically to the osteotomy: one of the screws in the plate penetrated the proximal radioulnar joint, interfering with forearm rotation; a second procedure was required to shorten the screw. Only one of the 17 patients requested plate removal during the 32 month (average) follow-up period. Plate fixation of olecranon osteotomies using a 3.5 mm reconstruction plate provides a construct with predictable healing and few complications. The overall results using this technique are comparable with other reported methods in the literature.

Bone Plates↗