PubMed HealthSearch

PubMed · 3535550

Soft tissue fixation to bone.

Abstract

This experiment was designed to compare the immediate fixation strengths of various methods of soft tissue fixation techniques. The fixation techniques tested were the barbed staple, stone staple, suture techniques, screw with spiked plastic washer, and the screw with spiked soft tissue plate. Cadaveric soft tissue specimens were classified into three distinct morphologic types: capsular, tendinous, and extensor mechanism tissue. Each specimen was fixed to bone by one of the fixation techniques. The specimens were loaded in a cyclical fashion until fixation failure occurred. One hundred thirty-seven trials were performed. The screws with the spiked plastic washer and soft tissue plate proved superior overall for all three tissue types. The stone staple was the poorest technique tested. Therefore, if cyclic loading or tension is anticipated at the fixation site, the fixation technique of choice would be the screw with spiked plastic washer or soft tissue fixation plate.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D B Robertson, D M Daniel, E Biden. Soft tissue fixation to bone.. https://doi.org/10.1177/036354658601400512

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Reliability of roentgenogram evaluation of pedicle screw position.

STUDY DESIGN: This was a human cadaver study of the accuracy of biplanar roentgenography in determining pedicle screw position. OBJECTIVE: To determine the independent accuracy of radiologic evaluation of screw placement and to determine if there are any particular screw malpositions that are more likely to produce a false sense of acceptable screw position. SUMMARY OF BACKGROUND DATA: Other investigators have reported the correlation between radiologic evaluation and anatomic dissection. However, in those studies the radiologic evaluation was not independent of the surgeons placing the screws. There has been no comment in the literature regarding particular screw malpositions that would lead the surgeon into a false sense of successful screw placement. METHODS: Pedicle screws were placed in cadaver spines, and biplanar roentgenograms of the specimens were evaluated by independent observers. The results of the roantgenogram evaluation then were compared to those of the anatomic dissection. RESULTS: The accuracy of roentgenogram evaluation varied from 73% to 83%, depending on the experience of the surgeon grading the roentgenograms. Screws misplaced medially into the spinal canal are more likely to give the surgeon a false sense of successful screw placement. CONCLUSIONS: The surgeon must not rely solely on the roentgenograms, but instead continue to use tactile sensory skills, anatomic knowledge, and additional modalities such as electromyography monitoring.

Bone Screws

Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients.

STUDY DESIGN: A prospective clinical trial was done to study the accuracy of pedicle screw placement in 30 consecutive computer-assisted orthopedic surgeries. OBJECTIVES: To determine the accuracy and clinical applicability of this new method for pedicle screw insertion. SUMMARY OF BACKGROUND DATA: Conventional screw insertion techniques have been associated with high pedicle screw malplacement rates in cadaver studies and clinical studies with postoperative computed tomography evaluation. METHODS: Thirty transpedicular, low-back, titanium instrumentations were performed with computer-assisted orthopedic surgery. The accuracy of screw placement was evaluated using a sophisticated computed tomography protocol. RESULTS: The total number of pedicle screws was 174. Of these, 139 (79.9%) could be inserted with computer-assisted orthopedic surgery. The malplacement rate of computer-assisted orthopedic surgery screws was 4.3%. In screws that were not inserted by computer-assisted orthopedic surgery, the malplacement rate was 14.3%. One malplaced screw that had not been inserted with computer-assisted orthopedic surgery caused L4 root paresis. CONCLUSIONS: The accuracy of pedicle screw placement using computer-assisted surgery proved to be superior to the accuracy obtained when using conventional techniques.

Bone Screws

In vitro simulation. Early results of stereotaxy for pedicle screw placement.

STUDY DESIGN: Frameless stereotaxy with doppler ultrasound and three dimensional computer model registration is assessed in vitro for pedicle screw placement. OBJECTIVE: To identify feasibility of pedicle screw navigation and placement using this technology. SUMMARY OF BACKGROUND DATA: Inaccurate pedicle screw placement can lead to neurovascular injury or suboptimal fixation. Present techniques in pedicle screw placement involve only confirmation of hole orientation. METHOD: Forty-four pedicle screws were placed in lumbosacral models and cadaver specimens. Accuracy was assessed with a computed tomography scan and vertebral cross sectioning. RESULTS: All screws were intrapedicular. Accuracy of anterior cortical fixation was 1.5 mm, with a range of 2.5 mm. CONCLUSION: In vitro frameless stereotaxy is accurate for pedicle screw placement. This technology adds a component of navigation to pedicle screw placement.

Bone Screws