Abstract

A little over 40 years ago, anesthesiology in the United States became recognized as a specialty. At that time, its practice was largely that of an art, the science of which was yet to come. A finger on the pulse, observation of color, skin turgor, perspiration, and perhaps a blood pressure cuff in adults, and an estimation of the reflex signs of anesthesia were the standards for the assessment of the patient status and 'the depth of anesthesia'. How far have we come in the intervening years? The journey, as reflected in the experience of one physician, will be held up to the looking-glass; easily as astounding as that through which Alice passed. Caught as we are in the socio-economic climate of the present, how shall we react? Has the gadgetry and electronics of this day given us a meaningful cost-effective handle on a decreased morbidity and mortality? What impact is there on decision-making and outcome? What indeed is the contribution of the machine versus the newer agents, techniques, and the advanced educational milieu. The first attempts at monitoring were clearly directed toward the cardiovascular system. The devices developed were simple and non-invasive. The Riva-rocci method of measuring blood pressure was first applied in anesthesia by Harvey Cushing at the turn of the century. But it was 40 years before the electrocardiogram was introduced as an instrument of potential importance. It took another 25 years for it to have general acceptance, and even later for the anesthesiologist to become comfortable with it as a diagnostic tool.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M H Harmel. 1986. Monitoring, past, present, future. A personal journey.. https://doi.org/10.1007/bf01880768

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Perception of training needs and opportunities in advanced airway skills: a survey of British and Irish trainees.

BACKGROUND AND OBJECTIVE: We surveyed delegates at the Group of Anaesthetists in Training (UK) meeting to investigate evidence of a training-gap (number of fibreoptic intubations believed to bestow competence vs. number actually performed). METHODS: Questionnaires were distributed to and collected from delegates in person. Questions covered six areas, including experience of fibreoptic intubation and cricothyrotomy, fibreoptic intubation as a specialist skill and ethical issues. RESULTS: We received 221 replies (76%). All trainees believed competence to be achievable with 10 intubations (interquartile range (IQR) 10-20); the median number performed was 2 (IQR 0-4). This was statistically significant for the groups' senior house officers, 1st and 2nd year registrars and 3rd and 4th year registrars; P < 0.0001. Many final year trainees (12/20, 60%) also failed to achieve their competency target. Few trainees had seen or performed any cricothyrotomies (medians 0, IQRs 0-1 and 0-0). Most (195/208, 94%) believed that fibreoptic intubation was a core skill and 199/212 (94%) believed that all should be competent by completion of training. Ten percent (n = 208) felt it unethical to perform an awake training intubation with full consent and 10% believed it acceptable without explanation. Most (82.7%) would fibreoptically intubate an asleep patient (requiring intubation) without consent. CONCLUSION: Trainees reported a gap between their perception of competence and achievement in awake fibreoptic intubation. Simple and complex simulations and structured training programmes may help. Anaesthetists must address the ethics of clinical training in advanced airway management.

Anesthesiology↗