PubMed HealthSearch

PubMed · 35443

[Telemetric monitoring of delivery when inducing labour by prostaglandin E2 tablets (author's transl)].

Abstract

The article reports on 75 patients in whom labour had been introduced by means of oral administration of prostaglandin E2 tablets (35 patients were controlled at the bedside and 40 patients were monitored telemetrically.) Telemetric monitoring is preferable in oral application of ecbolics, since this entails a saving in ecbolics (4.7 as against 5.4 tablets), regular labour is induced more rapidly (after 57 as against 72 minutes) and total delivery time is shortened (4 hours 24 minutes as against 5 hours 15 minutes). There were no serious side effects neither in the mother nor in the neonate. 6 of the 75 patients complained of slight gastrointestinal side effects. The Apgar scores and pH levels of the children were in the normal range. The post-partum period was identical in both groups, namely, 11 minutes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Steiner, D Robrecht, H P Zahradnik, F Mross, H G Hillemanns. 1979. [Telemetric monitoring of delivery when inducing labour by prostaglandin E2 tablets (author's transl)].. https://pubmed.ncbi.nlm.nih.gov/35443/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The influence of scalp sampling on the cesarean section rate for fetal distress.

One year's obstetric experience at Los Angeles County-University of Southern California Medical Center was reviewed and compared with previous years. The incidence of cesarean section for fetal distress is low and has remained constant over the past 7 years. Periodic changes and decreased baseline variability of the fetal heart rate accounted for 39% of the diagnoses of fetal distress in this group. Scalp sampling clarified the diagnosis of fetal distress and prevented unnecessary cesarean section. Compromised perinatal outcome in the greater than 2,500 gram weight group was confined to those who were monitored, had indications for monitoring, or had identifiable prospective risk factors, with rare exceptions.

Apgar Score

The relationship of heart rate patterns and tissue pH in the human fetus.

The relationship between different FHR patterns and fetal tissue pH in 68 high-risk gravidas in labor was analyzed. A tissue pH electrode was placed in the fetal scalp and tissue pH recorded on a fetal monitor every 15 seconds along with uterine contractions and continuous fetal heart rate. The tissue pH changes correlated with the FHR patterns in a manner consistent with current concepts of fetal stress. Trend monitoring of fetal tissue pH in labor may prove useful in the management of high-risk patients in labor.

Apgar Score

Fetal heart rate variability: an approach to automated assessment.

Three hundred seventy-five hours of fetal heart rate (FHR) data derived from the direct fetal electrocardiogram (ECG) were studied. This data had been stored on magnetic tape from 83 intrapartum patients. By means of a computerized technique, the FHR variability was assessed quantitatively. The degree of variability was then related to: (1) state of labor, (2) fetal scalp pH values, and (3) the 1-minute Apgar score. FHR variability was computed from differences between consecutive R-R intervals measured from the R wave of each fetal ECG. A trend of increasing variability was seen with advancing labor, defined by either time prior to delivery or cervical dilatation, but values were not statistically significant. Significantly less FHR variability was encountered when fetal scalp pH values below 7.20 were compared to higher values. FHR variability assessed during the 20 minutes immediately preceding delivery was significantly lower in infants with 1-minute Apgar scores less than 7. Machine assessment of FHR variability thus could be correlated with fetal condition as determined by scalp pH and neonatal outcome determined by Apgar score.

Apgar Score