Abstract

As part of a training programme for younger doctors, two commercially available, emergency cricothyroidotomy sets were evaluated. Prior to the surgical procedure, half of the doctors in each group received an audiovisual lesson. In a simulated but realistic emergency situation, involving autopsy material, cricothyroidotomy was performed utilizing either the "Nutrake" or the "Gentofte" system. The audiovisual lesson increased the speed and the success rate of the doctors performing this procedure as well as strengthening their confidence. Both systems allowed positive pressure ventilation. The participating doctors achieved a higher success rate at a faster speed with the "Nutrake" set.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O Ravlo, V Bach, H Lybecker, J T Møller, M Werner, H K Nielsen. 1987. A comparison between two emergency cricothyroidotomy instruments.. https://doi.org/10.1111/j.1399-6576.1987.tb02575.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Which patients benefit from percutaneous mitral balloon valvuloplasty? Prevalvuloplasty and postvalvuloplasty variables that predict long-term outcome.

BACKGROUND: Percutaneous mitral balloon valvuloplasty (PMV) results in good immediate results, particularly in patients with echocardiographic scores (Echo-Sc) < or =8. However, which variables relate to long-term outcome is unclear. METHODS AND RESULTS: We report the immediate and long-term clinical follow-up (mean, 4.2+/-3.7 years; range, 0.5 to 15) of 879 patients who underwent 939 PMV procedures. Patients were divided into 2 groups, Echo-Sc < or =8 (n=601) and Echo-Sc >8 (n=278). PMV resulted in an increase in mitral valve area from 1.0+/-0.3 to 2.0+/-0.6 cm2 in patients with Echo-Sc < or =8 and from 0.8+/-0.3 to 1.6+/-0.6 cm2 in patients with Echo-Sc >8 (P<0.0001). Although adverse events (death, mitral valve surgery, and redo PMV) were low within the first 5 years of follow-up, a progressive number of events occurred beyond this period. Nevertheless, survival (82% versus 57%) and event-free survival (38% versus 22%) at 12-year follow-up was greater in patients with Echo-Sc < or =8 (P<0.0001). Cox regression analysis identified post-PMV mitral regurgitation > or =3+, Echo-Sc >8, age, prior surgical commissurotomy, NYHA functional class IV, pre-PMV mitral regurgitation > or =2+, and higher post-PMV pulmonary artery pressure as independent predictors of combined events at long-term follow-up. CONCLUSIONS: The immediate and long-term outcome of patients undergoing PMV is multifactorial. The use of the Echo-Sc in conjunction with other clinical and morphological predictors of PMV outcome allows identification of patients who will obtain the best outcome from PMV.

Catheterization↗