PubMed Health⌕ Search

PubMed · 3609066

Extravascular lung water.

Abstract

Extravascular lung water (idQw1) is measured in vivo from the difference in mean transit times, computed by extrapolating the dilution curves, of two indicators, one freely diffusible, the other confined to the intravascular space. Using 3H2O it has been shown that idQw1 is smaller than the amount of extravascular water obtained from the difference between wet and dry lung weight (Qw1). Extrapolation allows one to use dilution curves for a short time, i.e., up to onset of obvious recirculation. Clearing the dilution curves or recirculation by deconvolution extends the observation time, which then becomes limited by sampling duration rather than onset of recirculation. This procedure entails recording recirculating tracers in the pulmonary artery (PA). Dilutions of tracers at input in PA and output in a systemic artery must be related to each other as continuous time functions. This is accomplished by means of a convolution integral. Deconvolution yields the frequency function of water molecule transit time in the extravascular lung space, l(t). In dogs and men, in both normal and edematous lungs, l(t) exhibits a knee and a fairly long tail. Extravascular lung water computed from l(t), idcQw1, agrees with Qw1 and correlates with data on the extravascular thermal volume of the lung and with radiographic findings of lung edema. A radiographic score of pulmonary edema may be used clinically to assess extravascular lung water in cardiac patients and in patients with adult respiratory distress syndrome.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Giuntini, M Pistolesi, M Miniati, F Fazio. 1987. Extravascular lung water.. https://doi.org/10.1007/bf00253294

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Assessing pulmonary permeability by transpulmonary thermodilution allows differentiation of hydrostatic pulmonary edema from ALI/ARDS.

OBJECTIVE: To test whether assessing pulmonary permeability by transpulmonary thermodilution enables to differentiate increased permeability pulmonary edema (ALI/ARDS) from hydrostatic pulmonary edema. DESIGN: Retrospective review of cases. SETTING: A 24-bed medical intensive care unit of a university hospital. PATIENTS: Forty-eight critically ill patients ventilated for acute respiratory failure with bilateral infiltrates on chest radiograph, a PaO(2)/FiO(2) ratio < 300 mmHg and extravascular lung water indexed for body weight >/= 12 ml/kg. INTERVENTION: We assessed pulmonary permeability by two indexes obtained from transpulmonary thermodilution: extravascular lung water/pulmonary blood volume (PVPI) and the ratio of extravascular lung water index over global end-diastolic volume index. The cause of pulmonary edema was determined a posteriori by three experts, taking into account medical history, clinical features, echocardiographic left ventricular function, chest radiography findings, B-type natriuretic peptide serum concentration and the time-course of these findings with therapy. Experts were blind for pulmonary permeability indexes and for global end-diastolic volume. MEASUREMENTS AND RESULTS: ALI/ARDS was diagnosed in 36 cases. The PVPI was 4.7+/-1.8 and 2.1+/-0.5 in patients with ALI/ARDS and hydrostatic pulmonary edema, respectively (p<0.05). The extravascular lung water index/global end-diastolic volume index ratio was 3.0 x 10(-2)+/-1.2 x 10(-2) and 1.4 x 10(-2)+/-0.4 x 10(-2) in patients with ALI/ARDS and with hydrostatic pulmonary edema, respectively (p<0.05). A PVPI >/= 3 and an extravascular lung water index/global end-diastolic index ratio >/= 1.8 x 10(-2) allowed the diagnosis of ALI/ARDS with a sensitivity of 85% and specificity of 100%. CONCLUSION: These results suggest that indexes of pulmonary permeability provided by transpulmonary thermodilution may be useful for determining the mechanism of pulmonary edema in the critically ill.

Capillary Permeability↗

Endothelial barrier function in preeclampsia.

Impaired endothelial barrier function resulting in increased vascular permeability is a characteristic vascular response in preeclampsia, a hypertensive and multiple systemic disorder of human pregnancy. During the last two decades, endothelial function in preeclampsia has been intensively studied and significant progress has been made in understanding the cellular and molecular bases of the altered endothelial cell response. In this review, we address the nature and mechanisms that are proposed to underlie the disturbed endothelial barrier function in preeclampsia and discuss the potential relevance of the endothelial cell responses to the initiation and/or progression of this vascular syndrome. Insights gained from the characterization of the endothelial cell phenotype assumed by the preeclamptic microvasculature may lead to novel therapeutic strategies for the management of this syndrome.

Capillary Permeability↗