Left ventricular image processing.

Abstract

Left ventricular image processing methods of x-ray cineangiocardiograms and ultrasound echocardiograms are discussed. 3-D reconstruction methods of the left ventricle from ultrasound echocardiograms and magnetic resonance images are also discussed. Boundary detection of the left ventricle and the quantitative analysis of the left ventricular function and wall motion are discussed. To reconstruct 3-D shapes, we need several cross sectional shapes or silhouettes of the left ventricle. Several cross sectional echo images of apical long axis view are taken by changing the angles of rotation of the probe of echo transducer around its axis. Gated multi-phase MRI method is used to obtain each 2 cross sectional images in transverse, coronal and sagittal directions. Some results of 3-D shapes of the left ventricle and myocardium reconstructed are shown and 3-D functional images which give us regional functions of the left ventricular wall on three dimensional shape are shown.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Eiho, M Kuwahara, N Asada. 1987. Left ventricular image processing.. https://doi.org/10.1007/978-94-009-3361-3_10

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Upper abdominal phase-contrast MR angiography: comparison of cine and non-cine techniques.

PURPOSE: To evaluate image quality, vessel conspicuity, and signal-to-noise ratio (S/N) of four two-dimensional magnetic resonance (MR) phase-contrast techniques: cine phase-contrast with respiratory compensation (CPC-R), cine phase-contrast without respiratory compensation (CPC), phase-contrast with two signals acquired (PC-2), and phase-contrast with eight signals acquired (PC-8). MATERIALS AND METHODS: MR angiographic images of the portal vein were obtained in 14 patients. RESULTS: Overall image quality was rated excellent in 10 of 14 patients (CPC-R), in one of 14 patients (CPC), in none of 14 patients (PC-2), and in one of 14 patients (PC-8). Views of 10 upper abdominal vessels were evaluated with each technique. The mean (+/- standard deviation) number of well-imaged vessels was 6 +/- 2 (CPC-R), 3 +/- 2 (CPC), 2 +/- 2 (PC-2), and 3 +/- 2 (PC-8). CPC-R images were significantly better in overall image quality and number of vessels seen (P < .01). Mean S/Ns were 10.8 +/- 3.4 (CPC-R), 6.8 +/- 2.7 (CPC), 4.5 +/- 1.7 (PC-2), and 6.4 +/- 2.1 (PC-8). S/N with CPC-R was significantly greater than with CPC, PC-2, or PC-8. CONCLUSION: CPC-R provided consistently higher quality angiographic images than were obtained with the other sequences studied.

Cineangiography

A new method for automatic identification of coronary arteries in standard biplane angiograms.

A new computerized method for analyzing biplane coronary arteriograms was proposed. The method extracted the vessels in an image, detected branching points, and identified vessel segments according to their anatomical names. The method was applied to a pair of orthogonal projection images acquired in the right anterior oblique and left anterior oblique views. It recognized the corresponding vessel segments in the images and labeled them correctly by their anatomical names. For diameter measurement, a combined first and second derivative filter process was applied to the images along the skeleton lines of the extracted vessel segments. We also designed a method of representation in which vessel diameters measured in the two projection images could be displayed in a single image.

Cineangiography

Automated extraction, labelling and analysis of the coronary vasculature from arteriograms.

For clinical decision-making and documentation purposes we have developed techniques to extract, label and analyze the coronary vasculature from arteriograms in an automated, quantitative manner. Advanced image processing techniques were applied to extract and analyze the vasculatures from non-subtracted arteriograms while artificial intelligence techniques were employed to assign anatomical labels. Lumen diameters of 11 phantom vessels were assessed with an accuracy of 0.27 +/- 0.19 mm (dtrue = 0.45 + 0.92dmeasured; r > 0.99) and 0.21 +/- 0.15 mm (dtrue = 0.42 + 0.91dmeasured; r > 0.99), from cine and digital images, respectively. We collected a total of 15 routinely acquired cine-arteriograms showing 74 vessel segments with 18 stenoses (severity larger than 30% assessed quantitatively), and 53 digital arteriograms showing 236 vessel segments with 69 stenoses. From the cine arteriograms we extracted 64 (86%) of the vessel segments without manual correction and 196 (83%) from the digital arteriograms. Repeated analysis (3 times) of the arteriograms by the same operator resulted in a standard deviation of the mean segment diameters (precision) of 0.064 mm for the cine-images and 0.020 mm for the digital images, while the standard deviations in the measurement of the minimal luminal diameter of the observed stenoses were 0.020 mm and 0.019 mm, respectively. The LAD artery, the septal and diagonal branches were correctly identified automatically in 86% of the segments. From these evaluations we conclude that our automated approach provides reliable tools for the assessment of multi-vessel disease, both in an off- and on-line environment.

Cineangiography