Occupational asthma from inhaled egg protein.

Abstract

We evaluated workers and performed an industrial hygiene assessment at a plant where raw eggs are processed into powdered egg yolk and whole egg. Egg dust levels in the packaging room straddled the American Conference of Governmental Industrial Hygienists' (ACGIH) exposure guideline of 10 mg/m3 for nuisance dust. We obtained medical histories from 25 workers, and performed physical examinations, spirometry, and serial determinations of peak expiratory flow rate (PEFR) by portable meter every 3 hrs (while awake) for 7 days. We defined symptomatic bronchial lability to be a decrement in PEFR on any one day of 20% or more of the day's maximum, with concurrent symptoms. Skin-prick tests and serum assays for specific IgE by the radioallergosorbent (RAST) method were performed to assess sensitivity to commercial egg proteins, egg protein fractions, and freshly prepared extracts of whole egg powder and yolk. We classified participants as definite cases of asthma if both the examining physician diagnosed asthma and symptomatic bronchial lability was demonstrated by serial PEFR determinations. Definite noncases of asthma were those participants in whom the physician did not diagnose asthma and in whom symptomatic bronchial lability was not demonstrated by PEFR. All five definite cases, compared to three of 16 definite noncases of asthma, had one or more positive skin-prick tests to egg proteins. Four of five cases, compared to 0 of 14 noncases, who had serum determinations, had an elevated RAST to one or more of the egg proteins. This study demonstrates that occupational asthma associated with IgE-mediated allergy to egg proteins occurs among workers exposed to inhaled egg proteins.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A B Smith, D I Bernstein, T C Aw, J S Gallagher, M London, S Kopp, G A Carson. 1987. Occupational asthma from inhaled egg protein.. https://doi.org/10.1002/ajim.4700120209. https://pubmed.health/record/pubmed%3A3661573/occupational-asthma-from-inhaled-egg-protein

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Exposure to mercury in the mine of Almaden.

OBJECTIVES: To describe the process for obtaining mercury and the historical exposure of Almadén miners to mercury. METHODS: Information on every workplace and historical data on production, technological changes in the productive process and biological and environmental values of mercury was collected. A job-exposure matrix was built with these values and the exposure to inorganic mercury was estimated quantitatively as mug/l of urine mercury. A cumulative exposure index was calculated for every worker by adding the estimates for every year in the different workplaces. RESULTS: In the mine, the highest exposures occurred during drilling, with values up to 2.26 mg/m3 in air, 2194 microg/l in urine and 374 microg/l in blood. Furnace operation and cleaning were the tasks with the highest values in metallurgy, peaking up to 3.37 mg/m3. The filling of bottles with mercury by free fall gave values within a range of 1.13-2.43 mg/m3 in air; these values dropped to 0.32-0.83 mg/m3 after introducing a new ventilation system. The toxicity effects of high doses of inorganic mercury on the central nervous and urinary systems have been known for decades. CONCLUSIONS: The exposure of the workers in Almadén mines to mercury has been very high. The extremely high content cinnabar ore of the mine explains the increased concentrations of mercury in air at the work places. This, together with inadequate working conditions, explains the high mercury levels found in blood and urine during the study period.

Air Pollutants, Occupational↗

Influence of start-up on PCDD/F emission of incinerators.

This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition after start-up, is 2-3 times higher than the mean of the others. For verifying the PCDD/F characteristics of incinerators during start-up, one continuous MSWI was investigated for two years. The elevated PCDD/F emissions of the MSWI during start-up could reach 96.9 ng I-TEQN m(-3) and still maintained a high PCDD/F emission (40 times higher than the Taiwan emission limit) even 18 h after the injection of activated carbon, indicating the memory effect. Taking the MSWI for example, which consists of four incinerators, the estimated annual PCDD/F emission from normal operational conditions was 0.112 g I-TEQ. However, one start-up procedure can generate approximately 60% of the PCDD/F emissions for one whole year of normal operations. And the PCDD/F emission, which is the result of the start-ups of four incinerators, was at least two times larger than that of a whole year's normal operations, without consideration for the PCDD/F emission contributed by the long lasting memory effect.

Air Pollutants, Occupational↗