PubMed Health⌕ Search

PubMed · 3668572

Patellar clonus: an autonomous central generator.

Abstract

The mechanisms underlying clonus are considered in relation to current theories. By the use of a lever attached to a printed motor forces have been applied to the upper edge of the patella, a steady stretching force in suitable hemiplegic patients started the clonic oscillations. With rhythmic forces it has been found that the underlying rhythm is very resistant to entrainment. The oscillation provoked by a steady bias is increased in amplitude but unchanged in frequency when inertia is added to the apparatus. The frequency of clonus at the ankle, patella and wrist is similar. These and other considerations lead to the conclusion that clonus is not due to the self re-excitation of stretch reflexes but to an autonomous central generator.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E G Walsh, G W Wright. 1987. Patellar clonus: an autonomous central generator.. https://doi.org/10.1136/jnnp.50.9.1225

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Modulation operated by the sympathetic nervous system on jaw reflexes and masticatory movement.

The sympathetic nervous system (SNS), that is activated under condition of physical, psychological and psychosocial stress, affects force production and fatigability of muscles by controlling both muscle blood flow and the intracellular contractile mechanism. In addition SNS may affect motor function by modulating afferent activity from muscle spindles that are highly concentrated in jaw-closing muscles. Possible implications of these actions on masticatory function and myofascial pain are discussed.

Electromyography↗

Abnormal responses to repetitive transcranial magnetic stimulation in multiple system atrophy.

We studied the response of the motor cortex to brief trains of suprathreshold repetitive transcranial magnetic stimulations (rTMS) in patients with the Parkinson-variant of multiple system atrophy (MSA-P) and compared it to patients with idiopathic Parkinson's disease (PD) and healthy controls. Eight subjects were studied in each group, and patients were matched for disease severity as assessed by Hoehn & Yahr stages. rTMS was delivered at rest and during low-level contractions in trains of 10 stimulations at 5 Hz, and stimulation intensity was set to result in an motor evoked potential (MEP) in the first dorsal interosseus muscle of 0.5 to 1.0 mV. In MSA-P, MEP amplitude at rest was already reduced after the second stimulus and remained so, while it did not change in PD and controls. During contraction, MEP size did not change during the train in any group. The silent period that followed the last stimulus was of similar duration as the first stimulus in MSA-P, but was increased in PD and controls. These findings indicate that abnormal inhibition occurs within the motor cortex in MSA-P, despite dopaminergic treatment and indicate differences in cortical dysfunction between MSA-P and PD. We suggest that these abnormalities reflect the motor cortex pathology found in MSA-P.

Electromyography↗