Extended caloric tests.

Abstract

The standard ABB remains the most popular test of vestibular function. The use of air caloric irrigations or the closed loop water system seem to be scientifically sound alternatives to the use of open water irrigation. Although controversy still surrounds the use of monothermal warm calorics as a screening test, several studies have shown its reliability. The Torok monothermal differential caloric test seems to be a good alternative to the ABB, but more studies need to be done showing its results in other hands. Some of the other tests mentioned in this report may be helpful as ancillary tests for use in patients in whom the standard tests produce inconsistent findings.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S J Wetmore. 1986. Extended caloric tests.. https://doi.org/10.1097/00003446-198606000-00011

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Implications of tissue heterogeneity for radiosurgery in head and neck tumors.

PURPOSE: This study was undertaken to investigate the perturbation of small radiation beams by low density heterogeneities and to evaluate the ability of a Monte Carlo code to account for such perturbation. Performance of an inexpensive film scanning system was also evaluated. METHODS AND MATERIALS: Film and diode measurements were made in an acrylic phantom in which the size and position of an air gap were varied. Monte Carlo analysis was used to obtain additional verification of the measurements, to provide insight into photon and electron transport phenomena not directly measurable, and as a benchmark for the code. RESULTS: With 10 MV photons and a 1 cm circular field, a small 3-mm air cavity placed 2.6 cm deep in acrylic (full buildup) results in a reduction in central axis dose of 21% immediately following the cavity. Equilibrium is then reestablished over the next centimeter, after which the dose exceeds that of the homogeneous case by 3-4%. The loss in central axis equilibrium is highly field-size dependent, with some loss occurring even for the largest (32 mm) collimator. In addition, the presence of the air cavity produces a significant increase in dose up to 2 cm lateral and outside the primary field. CONCLUSIONS: Tissue heterogeneities are not presently accounted for in radiosurgery calculations, yet have the ability to perturb dose significantly. Targets may potentially be underdosed, and adjacent critical structures overdosed. Inability to account for tissue heterogeneities may limit the use of the radiosurgery approach in some areas. A Monte Carlo approach may be the method of choice for small field dose calculation when tissue heterogeneities are encountered.

Air