PubMed Health⌕ Search

PubMed · 3724424

High-resolution human in vivo spectroscopic imaging using echo-time encoding technique.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H W Park, Z H Cho. 1986. High-resolution human in vivo spectroscopic imaging using echo-time encoding technique.. https://doi.org/10.1002/mrm.1910030310

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study.

Dose assessment in computed tomography (CT) is challenging due to the vast variety of CT scanners and imaging protocols in use. In the present study, the accurateness of a theoretical formalism implemented in the PC program CT-EXPO for dose calculation was evaluated by means of phantom measurements. Phantom measurements were performed with four 1-slice, four 4-slice and two 16-slice spiral CT scanners. Firstly, scanner-specific nCTDIw values were measured and compared with the corresponding standard values used for dose calculation. Secondly, effective doses were determined for three CT scans (head, chest and pelvis) performed at each of the ten installations from readings of thermoluminescent dosimeters distributed inside an anthropomorphic Alderson phantom and compared with the corresponding dose values computed with CT-EXPO. Differences between standard and individually measured nCTDIw values were less than 16%. Statistical analysis yielded a highly significant correlation (P < 0.001) between calculated and measured effective doses. The systematic and random uncertainty of the dose values calculated using standard nCTDIw values was about -9 and +/- 11%, respectively. The phantom measurements and model calculations were carried out for a variety of CT scanners and representative scan protocols validate the reliability of the dosimetric formalism considered-at least for patients with a standard body size and a tube voltage of 120 kV selected for the majority of CT scans performed in our study.

Head↗

Trendelenburg position, head elevation and a midline position optimize right internal jugular vein diameter.

PURPOSE: The right internal jugular (RIJ) is commonly used to provide central venous access, and success of cannulation shows a positive correlation with the vein's diameter. The purpose of this study is to establish the patient position resulting in the largest RIJ diameter. METHOD: 2D ultrasound was used to measure RIJ diameter, in varying body positions, in 21 healthy volunteers. RESULTS: In the neutral position (table flat, head on the table in midline) the RIJ diameter was (mean +/- standard deviation) 9.2 +/- 2.18 mm. A small pillow under the head increased RIJ diameter (10.6 +/- 2.16 mm, P < 0.001). Trendelenburg tilt of 15 degrees increased RIJ diameter (12.1 +/- 2.34 mm, P < 0.001). In the Trendelenburg position (15 degrees of tilt), a small pillow under the head further increased RIJ diameter (13.3 +/- 2.26, mm P < 0.001), palpating for the carotid artery decreased RIJ diameter (8.2 +/- 1.98 mm, P < 0.001), and rotation of the head 45 degrees to the left did not reduce RIJ diameter significantly (11.7 +/- 2.52 mm, P = 0.12). CONCLUSION: The patient position to achieve maximal RIJ diameter cannulation is: 15 degrees of Trendelenburg tilt; a small pillow or head ring under the head; the head in or close to midline; and after palpation of the carotid artery, it should be released prior to vein cannulation.

Head↗

Use of the anterolateral thigh flap for reconstruction of the head and neck.

PURPOSE OF REVIEW: The anterolateral thigh free flap has achieved recent popularity in North America for the reconstruction of head and neck defects after ablative surgery. The flap is most often based on either the septocutaneous or musculocutaneous perforators of the descending branch of the lateral circumflex femoral artery. Its versatility allows for a subcutaneous, fasciocutaneous, myocutaneous, or adipofascial flap to be obtained. RECENT FINDINGS: Recent publications have described the utility of the anterolateral thigh flap for reconstruction of head and neck defects. It has been used successfully in the reconstruction of the laryngopharynx, oral cavity, oropharynx, external skin, and maxilla. Furthermore, when a thinner flap is needed, a suprafascial anterolateral thigh flap may be raised or the flap may be thinned after it is obtained. SUMMARY: The anterolateral thigh flap is a highly versatile and reliable flap for use in the reconstruction of various soft tissue defects of the head and neck. This flap has gained great popularity in mainland China, Taiwan, and Japan given its versatility, ability for a two-team approach, and minimal donor site morbidity. However, it has not met the same enthusiasm in Europe and North America because of the relative difficulty in perforator dissection, reported variations of the vascular anatomy, and the presumed increased thickness of the anterolateral thigh tissue in the Western population in comparison with the patient population of the Far East. These obstacles may be overcome by increased surgical experience and by the ability to create a thinner suprafascial flap or thinning the flap after it has been obtained.

Head↗