PubMed Health⌕ Search

PubMed · 3753734

Cardioplegic solution: a contamination crisis.

Abstract

Eleven patients were given varying doses of cardioplegic solution contaminated with Enterobacter cloacae. Five patients died. Early bleeding, necessitating reoperation, occurred in eight patients and a total of 126 units of blood and 203 units of platelets were given (range 2 to 19 and 15 to 47 units, respectively). Mycotic aneurysms developed in four patients, rupturing between the ninth and eleventh postoperative day. Only one of these patients survived. Other complications included adult respiratory distress syndrome (three patients), renal failure (four patients), sternal infections (six patients), and organic brain syndrome (five patients). Although some factors of gram-negative septicemia were identified in retrospect, others were masked by the clinical setting in which it occurred. We recommend that each dose of cardioplegic solution be prepared on an individual basis and used immediately. We also recommend that "sternal blood" be cultured on all patients. The subtle features of "gram-negative septicemia" necessitate urgent investigation and treatment. The combination of low white cell count, high cardiac output, and low peripheral vascular resistance should be assumed to indicate septicemia until proved otherwise. A full coagulation screen including platelet function and fibrin degradation products should be performed in any and all patients with these findings. Mycotic aneurysms mandate urgent reoperation with interposition of a saphenous vein segment of these patients are to survive.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C F Hughes, A F Grant, B D Leckie, D K Baird. 1986. Cardioplegic solution: a contamination crisis.. https://pubmed.ncbi.nlm.nih.gov/3753734/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗