PubMed HealthSearch

PubMed · 3754802

An algorithm to manage variable-length records for highly portable clinical data base systems.

Abstract

An algorithm to archive patient data at free size in disk storage is presented. A record, assumed to be a character string such as an ASCII-coded text, is compressed and divided into fixed-length blocks. One block consists of a data field and a pointer field, and the blocks comprising a record are chained with pointers forwardly. A head pointer of each record is sequentially saved on a separate file. The data compression is performed as follows: if the same character code appears more than twice in succession, we count the number of the repetitions and save it with initial two characters. The algorithms for fetching, re-saving, and purging a record are also presented. These were implemented in FORTRAN77 and tested for performance using a practical patient data file. As the algorithm allows highly flexible record manipulation and can easily be implemented in conventional programming languages, it will make a useful tool for constructing a portable data base management system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Okada. 1986. An algorithm to manage variable-length records for highly portable clinical data base systems.. https://doi.org/10.1016/0010-4809(86)90018-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Transjugular intrahepatic portosystemic stent shunt (TIPSS) with use of Rösch-Uchida transjugular liver access set--evaluation by CT and its clinical application].

Appropriateness of the Rösch-Uchida transjugular liver access set designed for TIPSS procedure was confirmed, especially about the catheter angle and effective length of the 20 G puncture needle, by CT analysis on three dimensional vascular anatomy of the liver. Clinically, TIPSS using the set was successfully made for two patients, connecting superior right hepatic vein with right portal vein in one patient and middle hepatic vein with left portal vein in another patient with hypoplastic right portal vein. Prior to TIPSS procedure, verification of vascular anatomy on CT images is the key to success of TIPSS in safe.

Evaluation Studies as Topic

[Testing an ultrasonic scanner for determination of urinary bladder volume].

Bladderscan BVI 2000 is a portable ultrasound scanner, specially constructed for determination of bladder volume. We have tested this scanner for accuracy, systematic errors and the training required to use it. The bladder volumes measured by ultrasound scanning were compared with the true volumes. Fifty-six measurements were made. We found the accuracy of BVI 2000 sufficient to determine bladder volumes as either small or large. We found no systematic errors. No special training is required to use the scanner. The device is thus useful in most clinical situations when greater accuracy than indicated here is not necessary.

Evaluation Studies as Topic