PubMed HealthSearch

PubMed · 3840778

Flow determination using computed tomography: application to aortic dissection. Part I.

Abstract

The CT method of flow determination evaluated in this study was based on the application of contrast enhancement dynamics. In order to characterize flow, such parameters as mean transit time, rise time, peak CT value, curve width and variance, and others were derived from the venoarterial indicator dilution curves using a perfect mixers-in-series model of curve fitting analysis and a bolus injection of contrast medium. The technique was first validated in a steady state phantom model that simulated in vivo conditions of right-sided mixing closely by the introduction of a number of mixers. A series of flows through small tubes was measured. Good correlation was obtained (r = .85). For a fixed number of mixers, the central second moment of the primary peak of the indicator dilution curve or variance decreased with increasing flow and peak CT value increased. Applied to the clinical situation, this method would allow characterization of blood flow using an intravenous bolus of contrast.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D F Guthaner, M Nassi, B Bradley, R Tello. 1985. Flow determination using computed tomography: application to aortic dissection. Part I.. https://doi.org/10.1097/00004424-198510000-00005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Transesophageal echocardiography: technique, indications and findings].

The introduction of transesophageal echocardiography (TEE) as a 'semi-invasive' technique with few complications in clinical practice represents a major diagnostic advance in the evaluation of cardiac disease. The close anatomic vicinity of the transducer to the heart and thoracic aorta allows the use of high frequency devices with better resolution compared to transthoracic echocardiography. Furthermore, the diagnostic gain when evaluating structures that are poorly visualized by the transthoracic approach such as the left atrial appendage, interatrial septum, prosthetic valves and the thoracic aorta is highly improved by TEE. Major indications for TEE include the search for a cardiac source of embolism and cardiac tumors, the work-up prior to balloon mitral valvuloplasty, the evaluation of prosthetic valves and the search for vegetations and aortic dissection. After a short summary of patient preparation, instrumentation and examination technique, the major indications, contraindications and complications are reviewed on the basis of our own experience and the literature.

Aortic Dissection

[Spontaneous dissection of the internal carotid artery].

A typical case history of spontaneous dissection of the internal carotid artery is presented. In young patients with cerebral ischemia, initial pain in the affected side of the head and neck, a possible provocative mechanism and a transient or even persistent Horner's syndrome are highly suggestive. The angiographic picture of carotid artery dissection is characteristic. Spontaneous resolution is common, and recurrence rare. Surgical treatment can therefore be reserved for individual cases with recurrent ischemia and caused by emboli originating in the dissected segment of the artery.

Aortic Dissection