Ion-selective electrode technology: an overview.

Abstract

Diluting a sample before analysis, as is required by both flame photometry and indirect reading ISE analysers, gives less relevant analytical results than measuring an undiluted sample directly. This is because dilution masks the impact that protein and lipids exert on the true activity of an ion in a clinical sample. Measuring a sample directly without dilution enables only those ions which are not bound to other materials, e.g. other ions or proteins, to be detected. The levels of these free ions are more likely to reflect true physiological status than analysis of both free and bound ions. Measuring a sample of whole blood directly without dilution can only be performed accurately if the ISE analyser reference junction is unaffected by changes in haematocrit. Calibrant compositions should be of an ionic strength similar to that of physiological samples. Residual liquid junction potentials between calibrants and samples should be minimised by careful design of the reference electrode.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R F Burns, L J Russell. 1985. Ion-selective electrode technology: an overview.. https://pubmed.ncbi.nlm.nih.gov/3842335/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Significance of the automated blood count].

Modern hematology depends on rapid and accurate determination of quantitative and qualitative blood counts. Fully automated analyzers based on the principles of flow cytometry have replaced the traditional blood smear in the routine laboratory. They count the number of red cells, platelets and leukocytes with high precision. In addition, they divide the cells into different populations according to their physical or chemical properties. This population distribution pattern mimics a "differential" blood smear. Normality can be assessed with a high degree of accuracy, rapidly and reproducibly. The qualitative changes frequently provide pointers to the final diagnosis. In case of abnormalities the reports are flagged. A microscopic analysis should be added according to internal laboratory guidelines. It clarifies pathological findings and is essential in the search for specific abnormalities such as malaria. This underlines the need for exchange of information between physician and laboratory.

Autoanalysis

Fast liquid chromatography for the determination of drugs in plasma and combination with liquid-solid extraction in a fully automated system.

Fast liquid chromatography was applied to the assay of several drugs in plasma. Short columns, 3.3-4 cm long, packed with C18 material, 3 microns particle size, were used. The peaks were little subject to extra-column band-broadening because the investigated drugs were eluted with high capacity factors in order to obtain an adequate separation from plasma components. The main influences on efficiency were the response time of the detector and the solvent composition of the injected sample. Conventional apparatus was used. A fully automated analytical system combining liquid-solid extraction via disposable extraction columns and fast liquid chromatography on a small-dimensioned 3 microns particle size column is described for the assay of drugs in plasma. Automation was accomplished by using the Automatic Sample Preparation with Extraction Columns system.

Autoanalysis