PubMed Health⌕ Search

PubMed · 3856012

Rebasing metal-based complete mandibular dentures.

Abstract

A comprehensive rationale and technique is presented for rebasing a metal-based mandibular complete denture. It is economically practical to rebase the metal-based complete denture if it meets the criteria for rebasing. No more chair time is required for replacing a metal base than for an acrylic resin base. The only additional cost is for construction of the new metal base in the laboratory.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J R Sherman, J Komorech. 1985. Rebasing metal-based complete mandibular dentures.. https://doi.org/10.1016/0022-3913(85)90083-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Penetration depth into dental casting alloys by Nd:YAG laser.

This study investigated the effect of laser-beam welding conditions [voltage (V) and spot diameter (mm)] on the penetration depth into dental casting alloys. Castings (3.0 mm x 8.0 mm x 50 mm) were prepared from the metals used in this study: commercially pure titanium (CP Ti), Ti-6Al-4V, Ti-6Al-7Nb, cobalt-chromium alloy (Co-Cr) and Type IV gold alloy. Two cast blocks of each metal were butted against one another at the 8.0 x 50-mm surfaces. They were then welded at their interface under the following conditions: voltage of 160-340 V, spot diameter of 0.4-1.6 mm, and pulse duration of 10 ms. After laser welding, the blocks were separated, and the penetration depth into each alloy was measured. The data were analyzed with the use of ANOVA at the p < 0.05 level of significance. The penetration depths were as follows: CP Ti (0.29-6.45 mm), Ti-6Al-4V (0.32-5.24 mm), Ti-6Al-7Nb (0.34-5.65 mm), Co-Cr (0.24-6.15 mm), and Type IV gold alloy (0.12-5.22 mm). The voltage and spot diameter affected the penetration depth into the metals tested. When the voltage increased and the spot diameter decreased, the penetration depth increased for each metal. Selecting suitable conditions for laser welding to obtain sufficient penetration depth for the optimal thickness of the metal is important when welding prostheses.

Dental Alloys↗

Comparative tensile strengths of preceramic and postceramic solder connectors using high-palladium alloy.

STATEMENT OF PROBLEM: It is not known whether different high-palladium alloys of similar composition possess comparable tensile strength properties associated with connector soldering. PURPOSE: The purpose of this study was to evaluate the tensile strength properties of 2 high-palladium alloys on soldered connectors under simulated pre-ceramic and post-ceramic soldering conditions. MATERIAL AND METHODS: Eighty cylindrical castings were fabricated (Rx Naturelle Plus alloy and Option alloy). The 40 castings for each alloy were subdivided into 2 groups of 20 each. In the first group, castings for each alloy were randomly paired and soldered with presolder (SMG2) to produce 10 preceramic test connector specimens for each alloy. In the second group, castings were similarly paired and soldered with postsolder (490 fine) to produce 10 postceramic test connector specimens for each alloy. Each soldered connector was subjected to tensile force until failure in a universal testing machine. Statistical analysis using a Wilcoxon rank sums test was performed (alpha=.05) RESULTS: No significant difference was found between the mean tensile failure stress for Rx Naturelle Plus preceramic solder (344.7 +/- 77.6 MPa) compared to Option preceramic solder (411.5 +/- 112.8 MPa) (P =.1202). However, the mean tensile failure stress for Rx Naturelle Plus postceramic solder (260.8 +/- 223.7 MPa) was significantly lower than the Option postceramic solder (312.6 +/- 120.8 MPa) (P =.0407). Not only did Rx Naturelle Plus postceramic solder connectors show evidence of lower strength, but also an increased variation among specimens. CONCLUSIONS: Rx Naturelle Plus solder connectors provided better strength with the preceramic as opposed with the postceramic connectors. For postsolder connectors, Rx Naturelle Plus alloy had less acceptable strength and a wider variation, suggesting it is more technique sensitive than Option alloy connectors.

Dental Alloys↗

Frictional evaluations of dental typodont models using four self-ligating designs and a conventional design.

Abstract: After a previous study using typodonts and three standardized archwire (AW) sizes, the frictional evaluations of four self-ligating brackets were directed toward the optimal AW-bracket system. Four participating manufacturers suggested three AWs, which were a representation of the three stages of orthodontic treatment, to be coupled with their respective self-ligating design. Four replicated typodont models were mounted with a self-ligating design, and a fifth model was mounted with a conventional design that served as a control. The first experiment evaluated the manufacturer-suggested AWs against the respective self-ligating design. Because no third-stage AWs could engage their respective designs, a second experiment was implemented to gain more detailed analyses of the designs. This experiment included any successful manufacturer-suggested AWs from the first experiment against the four self-ligating designs and the control design. All self-ligating designs performed with the efficiency and reproducibility associated with expectations. Specifically, self-ligation outperformed the conventional brackets when coupled with up to 0.020- x 0.020-inch wires. The clearance of the various AW sizes and alloys changed with malocclusion. Furthermore, the parameter that best correlated with drawing forces was the bending stiffness of the AW, which was directly associated with the nominal dimension of each wire. The best AW-bracket system can be selected, when taking into account the stiffness (elastic modulus and size of the AW) along with the amount of malocclusion present, once the treatment plan is determined.

Dental Alloys↗