Valvar prosthetic dysfunction. Localisation and evaluation of the dysfunction using the Doppler technique.

Abstract

Thirty patients with 33 mitral or aortic prostheses or both were examined using the pulsed Doppler technique combined with cross sectional echocardiography to study the applicability of the Doppler technique in the diagnosis and evaluation of the severity of prosthetic dysfunction and to assess the ability of the mapping procedure to estimate the site and the size of the prosthetic defect. The dysfunction was valvar regurgitation in 29 instances and stenoses in eight, all of which were confirmed by invasive procedures. The severity of the dysfunction was graded on a three point scale. A control group of 73 subjects with 88 normal prostheses also underwent pulsed Doppler and cross sectional echocardiography. The pulsed Doppler study followed the usual procedure for a valvar disease including two and three dimensional mapping for regurgitation. Eight patients also underwent a continuous wave Doppler examination. The diagnostic reliability of the pulsed Doppler technique was greater than or equal to 90%. The severity of the dysfunction was accurately assessed in 86% of cases. In the case of aortic regurgitation, mapping of the jets was performed as easily for prostheses as for native regurgitant valves. In the case of mitral regurgitation, the mapping patterns depended on the cause of the dysfunction. With valvar tears, a jet was detected at the centre of the annulus, and with paravalvar leaks eccentric atrial jets were seen opposite the site of the leak. The pulsed Doppler and the surgical findings correlated well for both the site of the dysfunction (16/20 (80%) patients) and the size of the leak (13/16 (81%) patients). Thus, despite some limitations, pulsed Doppler and particularly the mapping procedure provide sufficient information to give an accurate non-invasive assessment of prosthetic valve dysfunction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Veyrat, S Witchitz, A Lessana, A Ameur, G Abitbol, D Kalmanson. 1985. Valvar prosthetic dysfunction. Localisation and evaluation of the dysfunction using the Doppler technique.. https://doi.org/10.1136/hrt.54.3.273

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transcatheter umbrella closure of valvular and paravalvular leaks.

OBJECTIVES: Our aim was to adapt the technique of transcatheter umbrella closure of intracardiac defects for closure of valvular and paravalvular defects. BACKGROUND: The double-umbrella device developed by Rashkind and Cuaso has been safely and effectively delivered across a host of intracardiac defects, but transcatheter closure of valvular and paravalvular leaks has not been reported. METHODS: Between February 1987 and September 1990, eight patients who were believed to be poor operative candidates were taken to the catheterization laboratory for transcatheter double-umbrella closure of a valvular or a paravalvular leak. Four patients had a paravalvular leak around a prosthetic aortic valve. The other four patients had a valvular leak: one patient with a regurgitant native aortic valve after a Stansel procedure and three patients with a regurgitant porcine valve in a left ventricular apex to descending aorta conduit. RESULTS: Placement of a double-umbrella device was attempted in seven of the eight patients and was successful in all seven. Device placement was not attempted in one patient because of the crescentic shape of his defect. Two patients required two devices for each closure; the other five required only one device each. Angiography, performed on six patients after device closure, demonstrated that three patients had a completely occluded defect, two had trivial residual flow and one patient had mild residual flow through the device. All significant complications occurred in one patient who had hemolysis and oliguria that resolved when the initial umbrella was replaced by a larger device. In addition, two devices migrated to the patient's pulmonary arteries but were retrieved in the catheterization laboratory without difficulty. No other early or late complications occurred in 21 to 50 months of follow-up. Of the four patients with a paravalvular leak, the one who did not receive a device died at operation, one patient died at operation for an associated defect (in the operating room the umbrella was found securely in place across the paraaortic defect) and two patients are clinically well at home after 21 and 32 months, respectively. Of the four patients with closure of a valvular leak, one patient remains well at home 50 months later, one patient died at operation for associated defects and two patients had additional successful surgical treatment and remain well 29 months after device placement. CONCLUSIONS: Transcatheter umbrella closure appears to be a reasonable alternative for closure of a valvular or paravalvular leak in patients who are poor operative candidates.

Aortic Valve

[Results of heart valve replacement. Prognosis--occupational and general disability--occupational rehabilitation].

The success of valve surgery has led to a marked improvement in prognosis, quality of life and exercise tolerance in patients with symptomatic valvular heart disease. The degree of subjective and objective improvement depends on multiple preoperative factors like NYHA status, left ventricular function, valve lesion and type of valve replaced as well as peri- and postoperative factors like the occurrence of a perioperative myocardial infarction, the degree of intraoperative myocardial damage, the type of valve replaced and the speed and degree of postoperative regression of left ventricular hypertrophy and dilatation. The postoperative exercise tolerance is a major determinant for postoperative vocational rehabilitation. Therefore the individual functional assessment of patients postoperatively is of major importance.

Aortic Valve