Embedding method for electron microscopy in biology.

Abstract

Transmission electron microscopes were commercially available in some foreign countries in the later 1930s. Sectioning for light microscopy was used for electron microscopic observations of the internal structure of cells and tissues in the early days. Paraffin waxes were tested as embedding media, but they were too soft to enable thin sections. Pease and Baker (1948) (74) achieved an early success with the double-embedding method using the plastic "Parlodion" and paraffin wax.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Kushida. 1985. Embedding method for electron microscopy in biology.. https://pubmed.ncbi.nlm.nih.gov/3915837/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Staining etched epoxy resin sections for light microscopy.

Staining of etched sections for light microscopy is described. Azan staining was successful after treatment with potassium dichromate and the use of concentrated dye solutions. To remove osmium for hematoxylin-eosin staining, removal by reduction with ferrocene was used instead of oxidation. Highly selective differentiation after hematoxylin staining was achieved using p-toluenesulfonic acid-DMSO. To enhance eosin staining, a 2-bromoethylamine link between eosin and the tissue was used. Ferrocene also facilitated counterstaining of nuclei with hematoxylin after the PAS reaction. Periodic acid-methenamine silver staining was carried out without modification.

Epoxy Resins

[Whole organ plastination in otorhinolaryngology].

Total organ sections have proven to be useful in the evaluation of the clinical growth behavior of malignant tumors. However, histologic techniques using tissues embedded in celloidin or paraffin are difficult to produce and require extensive amounts of time. Total organ plastination is a method superior to the aforementioned techniques. The number of artefacts is also greatly reduced by avoiding the need for decalcification. After removal of fat and dehydration, specimens can be placed in epoxy resin. Following evacuation and hardening of specimens, parallel sections can be separated with a diamond wire saw for precision slicing, with section thicknesses ranging from several centimeters to as small as 40 microns. The loss in material caused by slicing is as little as 0.3 mm per section. A further benefit of this method is the relatively large amount of time saved. The entire procedure yielding complete plastinated specimens requires a time period of approximately 40 days. The plastinated specimens are transparent, odorless and fixed and are ideal for instructional and research purposes. Deplastination for the purpose of further diagnositic study is also achievable with a minimum of technical effort.

Epoxy Resins