PubMed · 394682
Wipe-rinse technique for quantitating microbial contamination on large surfaces.
Abstract
The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling areas sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 m2 (8.0 feet 2).
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
L E Kirschner, J R Puleo. 1979. Wipe-rinse technique for quantitating microbial contamination on large surfaces.. https://doi.org/10.1128/aem.38.3.466-470.1979