Microanalytical techniques for boron analysis using the 10B(n,alpha)7Li reaction.

Abstract

In order to predict the efficacy of boronated compounds for neutron capture therapy (NCT), it is mandatory that the boron concentration in tissues be known. Various techniques for measurement of trace amounts of boron (1-100 ppm) are available, including chemical and physical procedures. Experience has shown that, with the polyhedral boranes and carboranes in particular, the usual colorimetric and spark emission spectroscopic methods are not reliable. Although these compounds may be traced with additional radiolabels, direct physical detection of boron by nondestructive methods is clearly preferable. Boron analysis via detection of the prompt-gamma ray from the 10B(n, alpha)7Li reaction has been shown to be a reliable technique. Two prompt-gamma facilities developed at Brookhaven National Laboratory are described. One, at the 60-MW high flux beam reactor, uses sophisticated beam extraction techniques to enhance thermal neutron intensity and reduce fast neutron and gamma contamination. The other was constructed at Brookhaven's 5-MW medical research reactor and uses conventional shielding and electronics to provide an "on-line" boron analysis facility adjacent to beams designed for NCT, thus satisfying one of the requisites for clinical application of this procedure. Technical restrictions attendant upon the synthesis and testing of boronated biomolecules often require the measurement of trace amounts of boron in extremely small (mg) samples. A track-etching technique capable of detecting ng amounts of boron in mg liquid or cell samples is described. Thus it is possible to measure the boron content in small amounts (mg samples) of antibodies, or boron uptake in cells grown in tissue culture.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R G Fairchild, D Gabel, B H Laster, D Greenberg, W Kiszenick, P L Micca. Microanalytical techniques for boron analysis using the 10B(n,alpha)7Li reaction.. https://doi.org/10.1118/1.595962

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Targeting difficult accessible breast lesions: MRI-guided needle localization using a freehand technique in a 3.0 T closed bore magnet.

PURPOSE: To report the accuracy of magnetic resonance imaging (MRI)-guided needle localization for diagnosis of MRI detected suspicious breast lesions located in difficult accessible regions of the breast, using the freehand method in a 3.0 T closed bore magnet. MATERIALS AND METHODS: In five patients with five MRI-only breast lesions underwent MRI-guided needle localization for histopathologic evaluation of the lesions. All interventional procedures were performed in a 3.0 T MRI system with the patient in prone position and by using a dedicated phased array breast coil. MRI-guided needle localizations were performed by using a freehand technique. In our study, the high-resolution scan allowed preprocedural localization of all lesions without use of contrast enhancement. In all cases contrast-enhanced MRI was performed after insertion of the wire to confirm the tip of the wire in direct contact with the enhancing lesion. RESULTS: Needle localizations were performed in five patients. Histopathologic evaluation of tissue after surgery excision biopsy revealed one lymph node, three invasive ductal carcinoma and one ductal carcinoma in situ. Lesion size varied from 6 to 30 mm. Mean duration time was 25 min. No complications occurred during the intervention method. In the patient with the benign lesion control MRI of the breast after 6 months confirmed lesion removal. CONCLUSIONS: MRI-guided needle localization by using a freehand technique in a 3.0 T closed bore magnet is a safe and accurate method for diagnosis of difficult accessible breast lesions only visible on MRI.

Biopsy, Needle↗